Efficiency of inversion pulses for background suppressed arterial spin labeling
Abstract
Background suppression strategies for arterial spin labeling (ASL) MRI offer reduced noise from motion and other system instabilities. However, the inversion pulses used for suppression can also attenuate the ASL signal, which may offset the advantages of background suppression. Numerical simulations were used to optimize the inversion efficiency of four candidate pulses over a range of radiofrequency (RF) and static magnetic field variations typical of in vivo imaging. Optimized pulses were then used within a pulsed ASL sequence to assess the pulses' in vivo inversion efficiencies for ASL. The measured in vivo inversion efficiency was significantly lower than theoretical predictions (e.g., 93% experimental compared to 99% theoretical) for the tangent hyperbolic pulse applied in a background suppression scheme. This inefficiency was supported by an in vitro study of human blood. These results suggest that slow magnetization transfer (MT) in blood, either with bound water or macromolecular protons, dominates the inversion inefficiency in blood. Despite the attenuated signal relative to unsuppressed ASL, the signal‐to‐noise ratio (SNR) with suppression was improved by 23–110% depending on the size of the region measured. Knowledge of efficiency will aid optimization of the number of suppression pulses and provide more accurate quantification of blood flow. Magn Reson Med 54:366–372, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Self-citationDetermining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Adiabatic Pulses for Wideband Inversion and Broadband Decoupling
Kupce, E., & Freeman, R. (1995) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1995.1179 · Cited by 635
Mr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Silver, M. S., Joseph, R. I., & Hoult, D. I. (1985) · Physical Review A · doi:10.1103/physreva.31.2753 · Cited by 400
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Self-citationFrequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy
Ordidge, R. J., Wylezinska, M., Hugg, J. W., Butterworth, E., & Franconi, F. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360410 · Cited by 199
Alecci, M., Collins, C. M., Smith, M. B. H., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1201 · Cited by 130
Determination of Oxygen Extraction Ratios by Magnetic Resonance Imaging
Oja, J. M. E., GILLEN, J. S., Kauppinen, R. A., Kraut, M. A., & van Zijl, P. C. M. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199912000-00001 · Cited by 114
Three‐dimensional mapping of the static magnetic field inside the human head
Li, S., Dardzinski, B. J., Collins, C. M., Yang, Q., & Smith, M. B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360509 · Cited by 105
Multiple inversion recovery reduces static tissue signal in angiograms
Dixon, W. T., Sardashti, M., Castillo, M., & Stomp, G. P. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180202 · Cited by 97
The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling
Maccotta, L., Detre, J. A., & Alsop, D. C. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<216::aid-nbm468>3.0.co;2-u · Cited by 93
Self-citationSlice profile effects in adiabatic inversion: Application to multislice perfusion imaging
Frank, L. R., Wong, E. C., & Buxton, R. B. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380409 · Cited by 74
Effects of intracellular pH, blood, and tissue oxygen tension on T1ρ relaxation in rat brain
Kettunen, M. I., Gröhn, O. H. J., Silvennoinen, M. J., Penttonen, M., & Kauppinen, R. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10233 · Cited by 73
High‐sensitivity single‐shot perfusion‐weighted fMRI†
Duyn, J. H., Tan, C. X., van Gelderen, P., & Yongbi, M. N. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1163 · Cited by 52
Perfusion imaging using FOCI RF pulses
Yongbi, M. N., Branch, C. A., & Helpern, J. A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400622 · Cited by 47
Mulkern, R. V., Bowers, J. L., Heff, A., Guttmann, C. R. G., & Sadowski, R. H. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/2/004 · Cited by 5
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationDai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Self-citationApplications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Xu, G., Rowley, H. A., Wu, G., Alsop, D. C., Shankaranarayanan, A., Dowling, M., Christian, B. T., Oakes, T. R., & Johnson, S. C. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1462 · Cited by 280
Self-citation
Metadata
- Authors
- Garcia, D. M., Duhamel, G., & Alsop, D. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-07-19
- Volume
- 54
- Issue
- 2
- Pages
- 366-372
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2074155898
- Cited by
- 260
- References
- 19
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.