Characterization of the NMR behavior of white matter in bovine brain
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In vitro experiments on 15 white matter samples from five bovine brains were performed on a 1 H‐NMR spectrometer at 24°C and 37°C. The average myelin water fractions (MWFs) were 10.9% and 11.8% for samples at 24°C and 37°C, respectively. The T1 relaxation time at 37°C was found to be 830 ms, exhibiting monoexponential behavior. A four‐pool model including intra/extracellular (IE) water, myelin water, nonmyelin tissue, and myelin tissue was proposed to simulate the NMR behavior of bovine white matter. A cross‐relaxation correction was introduced to compensate for shifting of the measured data points and T2 times over the duration of the Carr‐Purcell‐Meiboom‐Gill (CPMG) measurement due to cross relaxation. This correction was found to be slight, providing evidence that MWFs measured using a multiecho technique are near physical values. At 24°C the cross‐relaxation times between myelin tissue and myelin water, myelin water and IE water, and IE water and nonmyelin tissue were found to be approximately 227, 2064, and 402 ms, respectively. At 37°C these same cross‐relaxation times were 158, 1021, and 170 ms, respectively. The exchange rate between myelin water and myelin was found to be 11.8 s−1 at 37°C, while the exchange rate between IE water and nonmyelin tissue was found to be 6.8 s−1. These exchange rates are of similar magnitude, which indicates that the interaction between IE water and nonmyelin tissue cannot be ignored. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
Self-citationA pathology–MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain
Moore, G. R. W., Leung, E., MacKay, A. L., Vavasour, I. M., Whittall, K. P., Cover, K. S., Li, D. K. B., Hashimoto, S. A., Oger, J., Sprinkle, T. J., et al. (2000) · Neurology · doi:10.1212/wnl.55.10.1506 · Cited by 185
Self-citation
Cited by
Gleaning multicomponent T1 and T2 information from steady‐state imaging data
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21704 · Cited by 472
Insights into brain microstructure from the T2 distribution
MacKay, A., Laule, C., Vavasour, I., Bjarnason, T., Kolind, S., & Mädler, B. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.037 · Cited by 347
Self-citationMagnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334
Self-citationDraganski, B., Ashburner, J., Hutton, C., Kherif, F., Frackowiak, R. S. J., Helms, G., & Weiskopf, N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.052 · Cited by 294
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Metadata
- Authors
- Bjarnason, T. A., Vavasour, I. M., Chia, C. L. L., & MacKay, A. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-09-30
- Volume
- 54
- Issue
- 5
- Pages
- 1072-1081
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2055302062
- Cited by
- 94
- References
- 4
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.