Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Instant MR labeling of stem cells using magnetoelectroporation

Walczak, P., Kedziorek, D. A., Gilad, A. A., Lin, S., Bulte, J. W. M.·2005·Magnetic Resonance in Medicine

Abstract

For cellular MR imaging, conventional approaches to intracellular magnetic labeling of nonphagocytic cells rely on the use of secondary compounds such as transfection agents and prolonged incubation of cells. Magnetoelectroporation (MEP) was investigated as an alternative method to achieve instant (<1 s) endosomal labeling with the FDA‐approved formulation Feridex, without the need for adjunct agents or initiating cell cultures. While MEP was harmful at higher voltages or pulse durations, the procedure could be properly calibrated using a pulse of 130 V and 17 ms. Labeling was demonstrated for stem cells from mice, rats, and humans; the uptake of iron was in the picogram range and comparable to values obtained using transfection agents. MEP‐labeled stem cells exhibited an unaltered viability, proliferation, and mitochondrial metabolic rate. Labeled mesenchymal stem cells (MSCs) and neural stem cells (NSCs) differentiated into adipogenic, osteogenic, and neural lineages in an identical fashion as unlabeled cells, while containing Feridex particles as demonstrated by double immunofluorescent staining. MEP‐labeled NSCs proliferated normally following intrastriatal transplantation and could be readily detected by MR imaging in vivo. As MEP circumvents the use of secondary agents, obviating the need for clinical approval, MEP labeling may be ideally suitable for bedside implementation. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20701

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 215

Metadata

Authors
Walczak, P., Kedziorek, D. A., Gilad, A. A., Lin, S., & Bulte, J. W. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-09-13
Volume
54
Issue
4
Pages
769-774
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2008776980
Cited by
215
References
1
FWCI
15.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Instant MR labeling of stem cells using magnetoelectroporation. https://app.cochat.ai/papers/10.1002/mrm.20701
The paper
Walczak, P., Kedziorek, D. A., Gilad, A. A., Lin, S., & Bulte, J. W. M. (2005). Instant MR labeling of stem cells using magnetoelectroporation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20701

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.