MR susceptometry for measuring global brain oxygen extraction
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Monitoring of oxygen saturation in jugular venous blood gives an estimate of the balance of global oxygen delivery and cerebral oxygen consumption. We present a noninvasive approach to measure oxygen saturation in vivo in the internal jugular vein using MR susceptometry by exploiting the characteristic susceptibility of deoxyhemoglobin, and demonstrate the feasibility of performing such measurements in a group of subjects. We assessed the sensitivity of the method for detecting small changes in oxygen saturation by monitoring the variations observed during breath‐holding and hypoventilation experiments. Unlike alternative methods, the susceptometric technique does not require calibration. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · cited 1×
“3 ms) of the agarose gel used for the flow experiment were very close to those of muscle at 3T (17).”
Method
Cited by
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
A novel background field removal method for MRI using projection onto dipole fields (PDF)
Liu, T., Khalidov, I., de Rochefort, L., Spincemaille, P., Liu, J., Tsiouris, A. J., & Wang, Y. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1670 · Cited by 455
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
“[5], and C is a block diagonal matrix representing pointwise multiplication, in which each diagonal block is the corresponding left-hand side vector in Eq.”
BackgroundMethodInfluentialLiu, T., Liu, J., de Rochefort, L., Spincemaille, P., Khalidov, I., Ledoux, J. R., & Wang, Y. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22816 · Cited by 376
Metadata
- Authors
- Fernández‐Seara, M. A., Techawiboonwong, A., Detre, J. A., & Wehrli, F. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-04-05
- Volume
- 55
- Issue
- 5
- Pages
- 967-973
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1963778885
- Cited by
- 146
- References
- 2
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR susceptometry for measuring global brain oxygen extraction. https://app.cochat.ai/papers/10.1002/mrm.20892
- The paper
- Fernández‐Seara, M. A., Techawiboonwong, A., Detre, J. A., & Wehrli, F. W. (2006). MR susceptometry for measuring global brain oxygen extraction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20892
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.