The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Localized short‐echo‐time proton MR spectroscopy with full signal‐intensity acquisition
Open accessAbstract
We developed a short‐echo‐time (TE) sequence for proton localized spectroscopy by combining a 1D add‐subtract scheme with a doubly slice‐selective spin‐echo (SE) sequence. The sequence preserves the full magnetization available from the selected volume of interest (VOI). By reducing the number of radiofrequency (RF) pulses acting on transverse magnetization, we were able to minimize the TE to the level that is achievable with the stimulated echo acquisition mode (STEAM) technique, and also gained a twofold increase in sensitivity. The use of an adiabatic pulse in the add‐subtract localization improved the efficiency of excitation in spatially inhomogeneous RF fields, which are frequently encountered at high magnetic fields. The localization performance and sensitivity gains of this method, which is termed SPin ECho, full Intensity Acquired Localized (SPECIAL) spectroscopy, were demonstrated in vivo in rat brains. In conjunction with spectroscopic imaging, a 2‐μl spatial resolution was accomplished with a signal‐to‐noise ratio (SNR) above 30, which is usually sufficient for reliable quantification of a large number of metabolites (neurochemical profile). Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Spatial Localization in NMR Spectroscopy in Vivo
BOTTOMLEY, P. A. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb32915.x · Cited by 1,378
In vivo1H NMR spectroscopy of rat brain at 1 ms echo time
Tk�?, I., Star?uk, Z., Choi, I.-Y., & Gruetter, R. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199904)41:4<649::aid-mrm2>3.0.co;2-g · Cited by 1,005
Self-citationLocalized proton spectroscopy using stimulated echoes
Frahm, J., Merboldt, K.-D., & Hänicke, W. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90154-5 · Cited by 826
Image-selected in Vivo spectroscopy (ISIS). A new technique for spatially selective nmr spectroscopy
Ordidge, R. J., Connelly, A., & Lohman, J. A. B. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90031-4 · Cited by 811
Field mapping without reference scan using asymmetric echo-planar techniques
Gruetter, R., & Tk�?, I. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<319::aid-mrm22>3.0.co;2-1 · Cited by 569
Self-citationIn vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394
Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopy
Moonen, C. T. W., Kienlin, M. V., Van Zijl, P. C. M., Cohen, J., Gillen, J., Daly, P., & Wolf, G. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020506 · Cited by 216
Öz, G., Terpstra, M., Tkáč, I., Aia, P., Lowary, J., Tuite, P., & Rolf Gruetter, A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20761 · Cited by 107
Localized Eddy Current Compensation Using Quantitative Field Mapping
Terpstra, M., Andersen, P. M., & Gruetter, R. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1353 · Cited by 61
Self-citation
Cited by
Larrieu, T., Cherix, A., Duque, A., Rodrigues, J., Lei, H., Gruetter, R., & Sandi, C. (2017) · Current Biology · doi:10.1016/j.cub.2017.06.027 · Cited by 202
Self-citationdas Neves Duarte, J. M., Kulak, A., Gholam-Razaee, M. M., Cuenod, M., Gruetter, R., & Do, K. Q. (2012) · Biological Psychiatry · doi:10.1016/j.biopsych.2011.07.035 · Cited by 124
Monin, A., Baumann, P. S., Griffa, A., Xin, L., Mekle, R., Fournier, M., Butticaz, C., Klaey, M., Cabungcal, J. H., Steullet, P., et al. (2015) · Molecular Psychiatry · doi:10.1038/mp.2014.88 · Cited by 113
MR connectomics: a conceptual framework for studying the developing brain
Hagmann, P., Grant, P. E., & Fair, D. A. (2012) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2012.00043 · Cited by 96
Duarte, J. M. N., Lanz, B., & Gruetter, R. (2011) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2011.00003 · Cited by 82
“Localized 1H NMR spectra were acquired using SPECIAL (Mlynárik et al., 2006) with echo time of 2.”
MethodInfluential
Metadata
- Authors
- Mlynárik, V., Gambarota, G., Frenkel, H., & Gruetter, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-09-21
- Volume
- 56
- Issue
- 5
- Pages
- 965-970
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1969772297
- Cited by
- 274
- References
- 13
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Localized short‐echo‐time proton MR spectroscopy with full signal‐intensity acquisition. https://app.cochat.ai/papers/10.1002/mrm.21043
- The paper
- Mlynárik, V., Gambarota, G., Frenkel, H., & Gruetter, R. (2006). Localized short‐echo‐time proton MR spectroscopy with full signal‐intensity acquisition. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.