The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency field
Abstract
A new method has been developed for fast image‐based measurements of the transmitted radiofrequency (RF) field. The method employs an actual flip‐angle imaging (AFI) pulse sequence that consists of two identical RF pulses followed by two delays of different duration (TR 1 < TR 2). After each pulse, a gradient‐echo (GRE) signal is acquired. It has been shown theoretically and experimentally that if delays TR 1 and TR 2 are sufficiently short and the transverse magnetization is completely spoiled, the ratio r = S2/S1 of signal intensities S1 and S2, acquired at the beginning of the time intervals TR 1 and TR 2, depends on the flip angle (FA) of applied pulses as r = (1 + n * cos(FA))/(n + cos(FA)), where n = TR 2/TR 1. The method allows fast 3D implementation and provides accurate B1 measurements that are highly insensitive to T1. The unique feature of the AFI method is that it uses a pulsed steady‐state signal acquisition. This overcomes the limitation of previous methods that required long relaxation delays between sequence repetitions. The method has been shown to be useful for time‐efficient whole‐body B1 mapping and correction of T1 maps obtained using a variable FA technique in the presence of nonuniform RF excitation. Magn Reson Med 57:192–200, 2007. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75611 · Cited by 800
The principle of reciprocity in signal strength calculations?A mathematical guide
Hoult, D. I. (2000) · Concepts in Magnetic Resonance · doi:10.1002/1099-0534(2000)12:4<173::aid-cmr1>3.0.co;2-q · Cited by 550
Rapid calculation of T1 using variable flip angle gradient refocused imaging
Fram, E. K., Herfkens, R. J., Johnson, G. A., Glover, G. H., Karis, J. P., Shimakawa, A., Perkins, T. G., & Pelc, N. J. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90021-x · Cited by 388
Imaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Cheng, H. M., & Wright, G. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20791 · Cited by 351
Mapping of the Radiofrequency Field
Insko, E. K., & Bolinger, L. (1993) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1993.1133 · Cited by 323
Spoiling of transverse magnetization in steady‐state sequences
Zur, Y., Wood, M. L., & Neuringer, L. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210210 · Cited by 306
Sled, J. G., & Pike, G. B. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730409 · Cited by 189
Radiofrequency map of an NMR coil by imaging
Akoka, S., Franconi, F., Seguin, F., & Le Pape, A. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90078-r · Cited by 164
Venkatesan, R., Lin, W., & Haacke, E. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400412 · Cited by 151
Collins, C. M., Yang, Q., Wang, J. H., Zhang, X., Liu, H., Michaeli, S., Zhu, X. H., Adriany, G., Vaughan, J. T., Anderson, P., et al. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10153 · Cited by 131
Parker, G. J. M., Barker, G. J., & Tofts, P. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1112 · Cited by 112
In vivo method for correcting transmit/receive nonuniformities with phased array coils
Wang, J., Qiu, M., & Constable, R. T. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20377 · Cited by 110
Hornak, J. P., Szumowski, J., & Bryant, R. G. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060204 · Cited by 104
Quantitative spectroscopic imaging of the human brain
Pan, J. W., Twieg, D. B., & Hetherington, H. P. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400305 · Cited by 102
Correction forB1 andB0 variations in quantitativeT2 measurements using MRI
Sled, J. G., & Pike, G. B. (2000) · Magnetic Resonance in Medicine · Cited by 93
A simple correction for B1 field errors in magnetization transfer ratio measurements
Samson, R. S., Wheeler‐Kingshott, C. A. M. G., Symms, M. R., Tozer, D. J., & Tofts, P. S. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.10.025 · Cited by 67
Assessment and correction of B1‐induced errors in magnetization transfer ratio measurements
Ropele, S., Filippi, M., Valsasina, P., Korteweg, T., Barkhof, F., Tofts, P. S., Samson, R. S., Miller, D. H., & Fazekas, F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20310 · Cited by 66
Trabecular bone volume fraction mapping by low‐resolution MRI
Fernández‐Seara, M. A., Song, H. K., & Wehrli, F. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1165 · Cited by 45
Cited by
The minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
Fragment Length of Circulating Tumor DNA
Underhill, H. R., Kitzman, J. O., Hellwig, S., Welker, N. C., Daza, R., Baker, D. N., Gligorich, K. M., Rostomily, R. C., Bronner, M. P., & Shendure, J. (2016) · PLOS Genetics · doi:10.1371/journal.pgen.1006162 · Cited by 671
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Trends and properties of human cerebral cortex: Correlations with cortical myelin content
Glasser, M. F., Goyal, M. S., Preuss, T. M., Raichle, M. E., & Van Essen, D. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.060 · Cited by 456
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Metadata
- Authors
- Yarnykh, V. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-12-26
- Volume
- 57
- Issue
- 1
- Pages
- 192-200
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2045527031
- Cited by
- 1,026
- References
- 20
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.