The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency field
Abstract
A new method has been developed for fast image‐based measurements of the transmitted radiofrequency (RF) field. The method employs an actual flip‐angle imaging (AFI) pulse sequence that consists of two identical RF pulses followed by two delays of different duration (TR 1 < TR 2). After each pulse, a gradient‐echo (GRE) signal is acquired. It has been shown theoretically and experimentally that if delays TR 1 and TR 2 are sufficiently short and the transverse magnetization is completely spoiled, the ratio r = S2/S1 of signal intensities S1 and S2, acquired at the beginning of the time intervals TR 1 and TR 2, depends on the flip angle (FA) of applied pulses as r = (1 + n * cos(FA))/(n + cos(FA)), where n = TR 2/TR 1. The method allows fast 3D implementation and provides accurate B1 measurements that are highly insensitive to T1. The unique feature of the AFI method is that it uses a pulsed steady‐state signal acquisition. This overcomes the limitation of previous methods that required long relaxation delays between sequence repetitions. The method has been shown to be useful for time‐efficient whole‐body B1 mapping and correction of T1 maps obtained using a variable FA technique in the presence of nonuniform RF excitation. Magn Reson Med 57:192–200, 2007. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75611 · Cited by 800
The principle of reciprocity in signal strength calculations?A mathematical guide
Hoult, D. I. (2000) · Concepts in Magnetic Resonance · doi:10.1002/1099-0534(2000)12:4<173::aid-cmr1>3.0.co;2-q · Cited by 550
Rapid calculation of T1 using variable flip angle gradient refocused imaging
Fram, E. K., Herfkens, R. J., Johnson, G. A., Glover, G. H., Karis, J. P., Shimakawa, A., Perkins, T. G., & Pelc, N. J. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90021-x · Cited by 388
Imaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Cheng, H. M., & Wright, G. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20791 · Cited by 351
Mapping of the Radiofrequency Field
Insko, E. K., & Bolinger, L. (1993) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1993.1133 · Cited by 323
Spoiling of transverse magnetization in steady‐state sequences
Zur, Y., Wood, M. L., & Neuringer, L. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210210 · Cited by 306
Sled, J. G., & Pike, G. B. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730409 · Cited by 189
Radiofrequency map of an NMR coil by imaging
Akoka, S., Franconi, F., Seguin, F., & Le Pape, A. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90078-r · Cited by 164
Cited by
The minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
Fragment Length of Circulating Tumor DNA
Underhill, H. R., Kitzman, J. O., Hellwig, S., Welker, N. C., Daza, R., Baker, D. N., Gligorich, K. M., Rostomily, R. C., Bronner, M. P., & Shendure, J. (2016) · PLOS Genetics · doi:10.1371/journal.pgen.1006162 · Cited by 671
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Trends and properties of human cerebral cortex: Correlations with cortical myelin content
Glasser, M. F., Goyal, M. S., Preuss, T. M., Raichle, M. E., & Van Essen, D. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.060 · Cited by 456
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
Helms, G., Dathe, H., Kallenberg, K., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21732 · Cited by 332
Determination of Electric Conductivity and Local SAR Via B1 Mapping
Katscher, U., Voigt, T., Findeklee, C., Vernickel, P., Nehrke, K., & DÖssel, O. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2015757 · Cited by 329
The Human Connectome Project: A retrospective
Elam, J. S., Glasser, M. F., Harms, M. P., Sotiropoulos, S. N., Andersson, J. L. R., Burgess, G. C., Curtiss, S. W., Oostenveld, R., Larson-Prior, L. J., Schoffelen, J.-M., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118543 · Cited by 307
Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout
Chung, S., Kim, D., Breton, E., & Axel, L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22423 · Cited by 304
7 Tesla MRI of the ex vivo human brain at 100 micron resolution
Edlow, B. L., Mareyam, A., Horn, A., Polimeni, J. R., Witzel, T., Tisdall, M. D., Augustinack, J. C., Stockmann, J. P., Diamond, B. R., Stevens, A., et al. (2019) · Scientific Data · doi:10.1038/s41597-019-0254-8 · Cited by 300
Multi-parametric neuroimaging reproducibility: A 3-T resource study
Landman, B. A., Huang, A. J., Gifford, A., Vikram, D. S., Lim, I. A. L., Farrell, J. A. D., Bogovic, J. A., Hua, J., Chen, M., Jarso, S., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.047 · Cited by 299
In vivo histology of the myelin g-ratio with magnetic resonance imaging
Stikov, N., Campbell, J. S. W., Stroh, T., Lavelée, M., Frey, S., Novek, J., Nuara, S., Ho, M.-K., Bedell, B. J., Dougherty, R. F., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.023 · Cited by 295
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285
DREAM—a novel approach for robust, ultrafast, multislice B1 mapping
Nehrke, K., & Börnert, P. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24158 · Cited by 282
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Wright, P. J., Mougin, O. E., Totman, J. J., Peters, A. M., Brookes, M. J., Coxon, R., Morris, P. E., Clemence, M., Francis, S. T., Bowtell, R. W., et al. (2008) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-008-0104-8 · Cited by 263
hMRI – A toolbox for quantitative MRI in neuroscience and clinical research
Tabelow, K., Balteau, E., Ashburner, J., Callaghan, M. F., Draganski, B., Helms, G., Kherif, F., Leutritz, T., Lutti, A., Phillips, C., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.029 · Cited by 256
Thrippleton, M. J., Backes, W. H., Sourbron, S., Ingrisch, M., van Osch, M. J. P., Dichgans, M., Fazekas, F., Ropele, S., Frayne, R., van Oostenbrugge, R. J., et al. (2019) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2019.01.013 · Cited by 252
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Microbiota influence the development of the brain and behaviors in C57BL/6J mice
Lu, J., Synowiec, S., Lu, L., Yu, Y., Bretherick, T., Takada, S., Yarnykh, V., Caplan, J., Caplan, M., Claud, E. C., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0201829 · Cited by 159
Self-citationFast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
“The two common ways to correct for the FA error are to premeasure the B1 or FA map (3,29,30), or to quantify B1 at the same time as the tissue parameters (28,31,32).”
Quantitative Gd‐DOTA uptake from cerebrospinal fluid into rat brain using 3D VFA‐SPGR at 9.4T
Lee, H., Mortensen, K., Sanggaard, S., Koch, P., Brunner, H., Quistorff, B., Nedergaard, M., & Benveniste, H. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26779 · Cited by 110
Pomares, F. B., Funck, T., Feier, N. A., Roy, S., Daigle-Martel, A., Ceko, M., Narayanan, S., Araujo, D., Thiel, A., Stikov, N., et al. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.2619-16.2016 · Cited by 108
Bane, O., Hectors, S. J., Wagner, M., Arlinghaus, L. L., Aryal, M. P., Cao, Y., Chenevert, T. L., Fennessy, F., Huang, W., Hylton, N. M., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26903 · Cited by 109
Evaluating g-ratio weighted changes in the corpus callosum as a function of age and sex
Berman, S., West, K. L., Does, M. D., Yeatman, J. D., & Mezer, A. A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.06.076 · Cited by 82
Teixeira, R. P. A. G., Malik, S. J., & Hajnal, J. V. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26670 · Cited by 39
Metadata
- Authors
- Yarnykh, V. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-12-26
- Volume
- 57
- Issue
- 1
- Pages
- 192-200
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2045527031
- Cited by
- 1,026
- References
- 20
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.