The DOI matches its Crossref record.
Fractional encoding of harmonic motions in MR elastography
Open accessAbstract
In MR elastography (MRE) shear waves are magnetically encoded by bipolar gradients that usually oscillate with the same frequency fv as the mechanical vibration. As a result, both the repetition time (TR) and echo time (TE) of such an MRE sequence are greater than the vibration period 1/fv. This causes long acquisition times and considerable signal dephasing in tissue with short transverse relaxation times. Here we propose a reverse concept with TR ≤ 1/fv which we call “fractional” MRE, i.e., only a fraction of one vibration cycle per TR, can be used for motion sensitization. The benefit of fractional MRE is twofold: 1) acquisition times in seconds can be achieved for a single‐phase difference wave image, and 2) materials that combine low elasticity, high viscosity, and short T relaxation times show an increased phase‐to‐noise ratio (PNR). A twofold increase of the phase signal is predicted for liver‐like materials. Volunteer studies performed in liver and biceps show the benefit of fractional MRE. Furthermore, we demonstrate the feasibility of the technique for in vivo myocardial MRE by visualizing transverse wave propagation in the interventricular septum (IVS). Magn Reson Med 57:388–395, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Klatt, D., Hamhaber, U., Asbach, P., Braun, J., & Sack, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/24/006 · Cited by 333
Self-citationMR elastography: Principles, guidelines, and terminology
Manduca, A., Bayly, P. V., Ehman, R. L., Kolipaka, A., Royston, T. J., Sack, I., Sinkus, R., & Van Beers, B. E. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28627 · Cited by 265
Self-citationAssessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264
Self-citationBrain mechanical property measurement using MRE with intrinsic activation
Weaver, J. B., Pattison, A. J., McGarry, M. D., Perreard, I. M., Swienckowski, J. G., Eskey, C. J., Lollis, S. S., & Paulsen, K. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7275 · Cited by 102
Metadata
- Authors
- Rump, J., Klatt, D., Braun, J., Warmuth, C., & Sack, I.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-01-26
- Volume
- 57
- Issue
- 2
- Pages
- 388-395
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2160371461
- Cited by
- 168
- References
- 0
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.