The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Assessment of liver viscoelasticity using multifrequency MR elastography
Open accessAbstract
MR elastography (MRE) allows the noninvasive assessment of the viscoelastic properties of human organs based on the organ response to oscillatory shear stress. Shear waves of a given frequency are mechanically introduced and the propagation is imaged by applying motion‐sensitive gradients. An experiment was set up that introduces multifrequency shear waves combined with broadband motion sensitization to extend the dynamic range of MRE from one given frequency to, in this study, four different frequencies. With this approach, multiple wave images corresponding to the four driving frequencies are simultaneously acquired and can be evaluated with regard to the dispersion of the complex modulus over the respective frequency. A viscoelastic model based on two shear moduli and one viscosity parameter was used to reproduce the experimental wave speed and wave damping dispersion. The technique was applied in eight healthy volunteers and eight patients with biopsy‐proven high‐grade liver fibrosis (grade 3–4). Fibrotic liver had a significantly higher (P < 0.01) viscosity (14.4 ± 6.6 Pa · s) and elastic moduli (2.91 ± 0.84 kPa; 4.83 ± 1.77 kPa) than the viscosity (7.3 ± 2.3 Pa · s) and elastic moduli (1.16 ± 0.28 kPa; 1.97 ± 0.30 kPa) of normal volunteers. Multifrequency MRE is well suited for the noninvasive differentiation of normal and fibrotic liver as it allows the measurement of rheologic material properties. Magn Reson Med 60:373–379, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Liver fibrosis – from bench to bedside
Friedman, S. L. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(02)00429-4 · Cited by 1,780
Ziol, M., Handra-Luca, A., Kettaneh, A., Christidis, C., Mal, F., Kazemi, F., de Lédinghen, V., Marcellin, P., Dhumeaux, D., Trinchet, J.-C., et al. (2005) · Hepatology · doi:10.1002/hep.20506 · Cited by 1,470
The Phenomenological Theory of Linear Viscoelastic Behavior
Tschoegl, N. W. (1989) · Springer eBooks · doi:10.1007/978-3-642-73602-5 · Cited by 1,328
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Hammel, P., Couvelard, A., O'Toole, D., Ratouis, A., Sauvanet, A., Fléjou, J. F., Degott, C., Belghiti, J., Bernades, P., Valla, D., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102083440604 · Cited by 427
Liver fibrosis: non‐invasive assessment with MR elastography
Huwart, L., Peeters, F., Sinkus, R., Annet, L., Salameh, N., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1030 · Cited by 417
Cited by
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659
Singh, S., Venkatesh, S. K., Wang, Z., Miller, F. H., Motosugi, U., Low, R. N., Hassanein, T., Asbach, P., Godfrey, E. M., Yin, M., et al. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.09.046 · Cited by 547
Self-citationThe impact of aging and gender on brain viscoelasticity
Sack, I., Beierbach, B., Wuerfel, J., Klatt, D., Hamhaber, U., Papazoglou, S., Martus, P., & Braun, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.040 · Cited by 423
Self-citationSingh, S., Venkatesh, S. K., Loomba, R., Wang, Z., Sirlin, C., Chen, J., Yin, M., Miller, F. H., Low, R. N., Hassanein, T., et al. (2016) · European Radiology · doi:10.1007/s00330-015-3949-z · Cited by 252
Self-citationGeneral review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Metadata
- Authors
- Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 60
- Issue
- 2
- Pages
- 373-379
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2037339586
- Cited by
- 264
- References
- 21
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of liver viscoelasticity using multifrequency MR elastography. https://app.cochat.ai/papers/10.1002/mrm.21636
- The paper
- Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008). Assessment of liver viscoelasticity using multifrequency MR elastography. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21636
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.