Is the “biexponential diffusion” biexponential?
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Diffusion‐weighted signal from the brain,S, deviates from monoexponential dependence on the b‐factor. This property is often referred to as biexponential diffusion, since the corresponding model fits data well. The aim of this study is to examine the necessity of using the biexponential model in homogeneous voxels under isotropic diffusion weighting up to b= 2.5 ms/μm 2. The model is compared to the cumulant expansion of ln S in a power series in b, which takes its origin in fundamental properties of the diffusion‐weighted signal, but diverges at large b. The absence of statistically significant evidences for the biexponential diffusion is demonstrated in gray matter. The cumulant expansion terminated after the term b2 describes data equally well with fewer adjustable parameters. The biexponential model is preferable in voxels with a partial volume of CSF. Magn Reson Med 57:464–469, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570 · cited 10×
“[1], is required by experimental data on a statistically significant level.”
BackgroundMethodInfluential
Cited by
MRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Self-citationWhite matter characterization with diffusional kurtosis imaging
Fieremans, E., Jensen, J. H., & Helpern, J. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.006 · Cited by 561
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Self-citationMR diffusion kurtosis imaging for neural tissue characterization
Wu, E. X., & Cheung, M. M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1506 · Cited by 346
Metadata
- Authors
- Kiselev, V. G., & Il'yasov, K. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-02-26
- Volume
- 57
- Issue
- 3
- Pages
- 464-469
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2080935328
- Cited by
- 128
- References
- 2
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is the “biexponential diffusion” biexponential? https://app.cochat.ai/papers/10.1002/mrm.21164
- The paper
- Kiselev, V. G., & Il'yasov, K. A. (2007). Is the “biexponential diffusion” biexponential? Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.