Gradient‐echo and CRAZED imaging for minute detection of Alzheimer plaques in an APPV717I × ADAM10‐dn mouse model
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Different strategies to visualize amyloid plaques with MRI at 17.6 Tesla were investigated in a novel mouse model of Alzheimer's disease (AD). Large iron‐containing plaques were observed in the thalamus, but cortical plaques did not show iron deposits. Plaques in the thalamus were visualized in vivo with the use of low‐resolution, 3D gradient‐echo (GRE) imaging in 82 s, and with 94‐μm resolution in 34 min. The feasibility of obtaining bright contrast from plaques using the COSY revamped with asymmetric z‐GRE detection (CRAZED) technique was investigated in experiments on fixed brains. The original CRAZED approach provided reduced signal near the plaques (similarly to GRE imaging) and additionally emphasized small structures in the brain. In CRAZED images acquired with mismatched gradients, elevated signal near the plaques was obtained, while background signal was suppressed almost to the noise level. Bright‐contrast images were acquired in 2.6 min with the use of a 2D GRE sequence with slightly mismatched slice refocusing gradients. For future detection of plaques in patients, such bright‐contrast visualization protocols may be of particular value when contrast agents that allow labeling of early plaques with iron oxide nanoparticles become available. Magn Reson Med 57:696–703, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
19F and 1H MRI detection of amyloid β plaques in vivo
Higuchi, M., Iwata, N., Matsuba, Y., Sato, K., Sasamoto, K., & Saido, T. C. (2005) · Nature Neuroscience · doi:10.1038/nn1422 · Cited by 339
In Vivo Magnetic Resonance Microimaging of Individual Amyloid Plaques in Alzheimer's Transgenic Mice
Jack, C. R., Wengenack, T. M., Reyes, D. A., Garwood, M., Curran, G. L., Borowski, B. J., Lin, J., Preboske, G. M., Holasek, S. S., Adriany, G., et al. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2588-05.2005 · Cited by 148
Cited by
Nanotechnology, nanotoxicology, and neuroscience
Suh, W. H., Suslick, K. S., Stucky, G. D., & Suh, Y.-H. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2008.09.009 · Cited by 406
Aggleton, J. P., Pralus, A., Nelson, A. J. D., & Hornberger, M. (2016) · Brain · doi:10.1093/brain/aww083 · Cited by 378
Collingwood, J. F., Chong, R. K. K., Kasama, T., Cervera-Gontard, L., Dunin-Borkowski, R. E., Perry, G., Pósfai, M., Siedlak, S. L., Simpson, E. T., Smith, M. A., et al. (2008) · Journal of Alzheimer's Disease · doi:10.3233/jad-2008-14211 · Cited by 147
“Iron deposits, associated with amyloid pathology and microbleeds, are increasingly noted in magnetic resonance imaging (MRI) studies [18,28,32,37,42].”
BackgroundA review of β-amyloid neuroimaging in Alzheimer's disease
Adlard, P. A., Tran, B. A., Finkelstein, D. I., Desmond, P. M., Johnston, L. A., Bush, A. I., & Egan, G. F. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00327 · Cited by 93
“Illustrating this difference, in the studies using T∗2-weighted GRE sequences only thalamic plaques were clearly visualized (Vanhoutte et al., 2005; Faber et al., 2007; Dhenain et al., 2009).”
BackgroundInfluentialWeidensteiner, C., Metzger, F., Bohrmann, A. B. B., Kuennecke, B., & von Kienlin, M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21985 · Cited by 56
“In an APP/ADAM10 AD mouse model, cortical plaques did not contain iron in contrast to plaques in the thalamus; consequently, plaques in the thalamus were visible in T*2-weighted images, whereas plaques in the cortex were not visible (41).”
Background
Metadata
- Authors
- Faber, C., Zahneisen, B., Tippmann, F., Schroeder, A., & Fahrenholz, F.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-03-27
- Volume
- 57
- Issue
- 4
- Pages
- 696-703
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2055898238
- Cited by
- 36
- References
- 2
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gradient‐echo and CRAZED imaging for minute detection of Alzheimer plaques in an APPV717I × ADAM10‐dn mouse model. https://app.cochat.ai/papers/10.1002/mrm.21201
- The paper
- Faber, C., Zahneisen, B., Tippmann, F., Schroeder, A., & Fahrenholz, F. (2007). Gradient‐echo and CRAZED imaging for minute detection of Alzheimer plaques in an APPV717I × ADAM10‐dn mouse model. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.