The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
Open accessAbstract
The reconstruction of artifact‐free images from radially encoded MRI acquisitions poses a difficult task for undersampled data sets, that is for a much lower number of spokes in k‐space than data samples per spoke. Here, we developed an iterative reconstruction method for undersampled radial MRI which (i) is based on a nonlinear optimization, (ii) allows for the incorporation of prior knowledge with use of penalty functions, and (iii) deals with data from multiple coils. The procedure arises as a two‐step mechanism which first estimates the coil profiles and then renders a final image that complies with the actual observations. Prior knowledge is introduced by penalizing edges in coil profiles and by a total variation constraint for the final image. The latter condition leads to an effective suppression of undersampling (streaking) artifacts and further adds a certain degree of denoising. Apart from simulations, experimental results for a radial spin‐echo MRI sequence are presented for phantoms and human brain in vivo at 2.9 T using 24, 48, and 96 spokes with 256 data samples. In comparison to conventional reconstructions (regridding) the proposed method yielded visually improved image quality in all cases. Magn Reson Med 57:1086–1098, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Nonlinear image recovery with half-quadratic regularization
Geman, D., & Yang, C. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.392335 · Cited by 1,000
A SURVEY OF NONLINEAR CONJUGATE GRADIENT METHODS
Hager, W. W., & Zhang, H. (2005) · Cited by 779
A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography
O'Sullivan, J. D. (1985) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1985.4307723 · Cited by 482
Principles of Magnetic Resonance Imaging
Liang, Z.-P., & Lauterbur, P. C. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470545652 · Cited by 412
Rapid gridding reconstruction with a minimal oversampling ratio
Beatty, P. J., Nishimura, D. G., & Pauly, J. M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.848376 · Cited by 333
Barger, A. V., Block, W. F., Toropov, Y., Grist, T. M., & Mistretta, C. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10212 · Cited by 291
Highly constrained backprojection for time‐resolved MRI
Mistretta, C. A., Wieben, O., Velikina, J., Block, W., Perry, J., Wu, Y., Johnson, K., & Wu, Y. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20772 · Cited by 274
Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling
Rahmer, J., Börnert, P., Groen, J., & Bos, C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20868 · Cited by 273
Inherently self‐calibrating non‐cartesian parallel imaging
Yeh, E. N., Stuber, M., McKenzie, C. A., Botnar, R. M., Leiner, T., Ohliger, M. A., Grant, A. K., Willig-Onwuachi, J., & Sodickson, D. K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20517 · Cited by 111
A fast and accurate Fourier algorithm for iterative parallel-beam tomography
Delaney, A. H., & Bresler, Y. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.495957 · Cited by 75
Analysis and comparison of motion‐correction techniques in diffusion‐weighted imaging
Trouard, T. P., Sabharwal, Y. S., Altbach, M. I., & Gmitro, A. F. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060614 · Cited by 74
MR Image Reconstruction from Sparse Radial Samples Using Bregman Iteration
He, L., & Fang, T. (2006) · Cited by 50
MR coronary vessel wall imaging: Comparison between radial and spiral k‐space sampling
Katoh, M., Spuentrup, E., Buecker, A., Manning, W. J., Günther, R. W., & Botnar, R. M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20569 · Cited by 42
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
Learning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392
Self-citationA deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
Metadata
- Authors
- Block, K. T., Uecker, M., & Frahm, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-05-29
- Volume
- 57
- Issue
- 6
- Pages
- 1086-1098
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2145020729
- Cited by
- 824
- References
- 21
- FWCI
- 15.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.