Modeling pulsed magnetization transfer
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Modeling the effects of clinical magnetization transfer (MT) scans, which generate contrast using short, shaped radiofrequency (RF) pulses (pulsed MT), is complex and time‐consuming. As a result, several studies have proposed approximate methods for a simplified analysis of the experimental data. However, potential differences in the MT parameters estimated by each method may complicate the comparison of reported results. In this study we evaluated three approximate methods currently used in quantitative MT (qMT) studies. In the first part of the investigation, an MT modeling technique that makes minimal approximations, other than the use of a two‐pool tissue representation, was developed and validated. Subsequently, this technique served as a standard against which to evaluate the other, more approximate models. Each model was used to fit experimental data from samples of wild‐type (WT) and shiverer mouse spinal cord, as well as simulated data generated by our minimal approximation modeling technique. The results of this study demonstrate that the approximations used in pulsed MT modeling are quite robust. In particular, it was shown that the semisolid pool fraction, M0B, which is known to correlate strongly with myelin content, and the transverse relaxation time of macromolecular protons, T2B, could be evaluated with reasonable accuracy regardless of the model used. Magn Reson Med 58:144–155, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Self-citationMolineaux, S. M., Engh, H., de Ferra, F., Hudson, L., & Lazzarini, R. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.19.7542 · Cited by 141
MR properties of excised neural tissue following experimentally induced inflammation
Stanisz, G. J., Webb, S., Munro, C. A., Pun, T., & Midha, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20008 · Cited by 138 · cited 1×
“[2], with the 1 term varying in time according to the RF pulse amplitude, B1.”
BackgroundSelf-citationSperfeld (1999) · Pure Amsterdam UMC · doi:10.1002/1531-8249(199911)46:5 · Cited by 2
Cited by
Zaiss, M., & Bachert, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/r221 · Cited by 323
Multi-parametric neuroimaging reproducibility: A 3-T resource study
Landman, B. A., Huang, A. J., Gifford, A., Vikram, D. S., Lim, I. A. L., Farrell, J. A. D., Bogovic, J. A., Hua, J., Chen, M., Jarso, S., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.047 · Cited by 299
Yarnykh, V. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23224 · Cited by 162
“Second, it can be measured with reasonable accuracy by different techniques (20).”
BackgroundMethodQuantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination
Thiessen, J. D., Zhang, Y., Zhang, H., Wang, L., Buist, R., Del Bigio, M. R., Kong, J., Li, X., & Martin, M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2992 · Cited by 148
Advanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Metadata
- Authors
- Portnoy, S., & Stanisz, G. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-07
- Volume
- 58
- Issue
- 1
- Pages
- 144-155
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2088159177
- Cited by
- 103
- References
- 7
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.