The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
MR tracking of transplanted cells with “positive contrast” using manganese oxide nanoparticles
Open accessAbstract
Rat glioma cells were labeled using electroporation with either manganese oxide (MnO) or superparamagnetic iron oxide (SPIO) nanoparticles. The viability and proliferation of SPIO‐labeled cells (1.9 mg Fe/ml) or cells electroporated with a low dose of MnO (100 μg Mn/ml) was not significantly different from unlabeled cells; a higher MnO dose (785 μg Mn/ml) was found to be toxic. The cellular ion content was 0.1–0.3 pg Mn/cell and 4.4 pg Fe/cell, respectively, with cellular relaxivities of 2.5–4.8 s−1 (R1) and 45–84 s−1 (R2) for MnO‐labeled cells. Labeled cells (SPIO and low‐dose MnO) were each transplanted in contralateral brain hemispheres of rats and imaged in vivo at 9.4T. While SPIO‐labeled cells produced a strong “negative contrast” due to the increase in R2, MnO‐labeled cells produced “positive contrast” with an increased R1. Simultaneous imaging of both transplants with opposite contrast offers a method for MR “double labeling” of different cell populations. Magn Reson Med 60:1–7, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
de Vries, I. J. M., Lesterhuis, W. J., Barentsz, J. O., Verdijk, P., van Krieken, J. H., Boerman, O. C., Oyen, W. J. G., Bonenkamp, J. J., Boezeman, J. B., Adema, G. J., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1154 · Cited by 821
Self-citation
Cited by
Kim, T., Momin, E., Choi, J., Yuan, K., Zaidi, H., Kim, J., Park, M., Lee, N., McMahon, M. T., Quinones-Hinojosa, A., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1084095 · Cited by 511
Self-citationIn vivo MRI cell tracking: clinical studies
Bulte, J. W. M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.3107 · Cited by 430
Self-citationManganese-based MRI contrast agents: past, present, and future
Pan, D., Schmieder, A. H., Wickline, S. A., & Lanza, G. M. (2011) · Tetrahedron · doi:10.1016/j.tet.2011.07.076 · Cited by 419
Multifunctional magnetic nanoparticles for medical imaging applications
Fang, C., & Zhang, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902182e · Cited by 312
Synthesis and bio-functionalization of magnetic nanoparticles for medical diagnosis and treatment
Schladt, T. D., Schneider, K., Schild, H., & Tremel, W. (2011) · Dalton Transactions · doi:10.1039/c0dt00689k · Cited by 286
Metadata
- Authors
- Gilad, A. A., Walczak, P., McMahon, M. T., Na, H. B., Lee, J. H., An, K., Hyeon, T., van Zijl, P. C. M., & Bulte, J. W. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-06-25
- Volume
- 60
- Issue
- 1
- Pages
- 1-7
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2126863379
- Cited by
- 159
- References
- 1
- FWCI
- 13.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.