The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
A general framework for experiment design in diffusion MRI and its application in measuring direct tissue‐microstructure features
Open accessAbstract
This article introduces a new and general framework for optimizing the experiment design for diffusion MRI of samples with unknown orientation. An illustration then uses the framework to study the feasibility of measuring direct features of brain‐tissue microstructure in vivo. The study investigates the accuracy and precision with which we can estimate potentially important new biomarkers such as axon density and radius in white matter. Simulation experiments use a simple model of white matter based on CHARMED (composite hindered and restricted model of diffusion). The optimization finds acquisition protocols achievable on modern human and animal systems that consist of 120 measurements with fixed maximum gradient strengths. Axon radii in brain tissue are typically in the range 0.25–10 μm. Simulations suggest that estimates of radii in the range 5–10 μm have highest precision and that a maximum gradient strength of 0.07 T m−1 is sufficient to distinguish radii of 5, 10, and 20 μm. Smaller radii are more difficult to distinguish from one another but are identifiable as small. A maximum gradient strength of 0.2 T m−1 distinguishes radii of 1 and 2 μm. The simulations also suggest that axon densities and diffusivity parameters in the normal range for white matter are recoverable. The experiment‐design optimization has applications well beyond the current work to optimize the protocol for fitting any model of the diffusion process. Magn Reson Med 60:439–448, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Microstructure of Temporo-Parietal White Matter as a Basis for Reading Ability
Klingberg, T., Hedehus, M., Temple, E., Salz, T., Gabrieli, J. D. E., Moseley, M. E., & Poldrack, R. A. (2000) · Neuron · doi:10.1016/s0896-6273(00)80911-3 · Cited by 731
Diffraction-like effects in NMR diffusion studies of fluids in porous solids
Callaghan, P. T., Coy, A., MacGowan, D., Packer, K. J., & Zelaya, F. O. (1991) · Nature · doi:10.1038/351467a0 · Cited by 649
Pfefferbaum, A., Sullivan, E. V., Hedehus, M., Lim, K. O., Adalsteinsson, E., & Moseley, M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<259::aid-mrm13>3.0.co;2-6 · Cited by 595
Assaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Diffusion and related transport mechanisms in brain tissue
Nicholson, C. (2001) · Reports on Progress in Physics · doi:10.1088/0034-4885/64/7/202 · Cited by 490
The role of diffusion tensor imaging in the evaluation of ischemic brain injury – a review
Sotak, C. H. (2002) · NMR in Biomedicine · doi:10.1002/nbm.786 · Cited by 433
Spin echo of spins diffusing in a bounded medium
Neuman, C. H. (1974) · The Journal of Chemical Physics · doi:10.1063/1.1680931 · Cited by 428
McKinstry, R. C. (2002) · Cerebral Cortex · doi:10.1093/cercor/12.12.1237 · Cited by 374
SOMA — Self-Organizing Migrating Algorithm
Zelinka, I. (2004) · Studies in Fuzziness and Soft Computing · doi:10.1007/978-3-540-39930-8_7 · Cited by 368
Self-Diffusion Coefficient of Liquid Lithium
Murday, J. S., & Cotts, R. M. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1668160 · Cited by 365
NMR microscopy of dynamic displacements: k-space and q-space imaging
Callaghan, P. T., Eccles, C. D., & Xia, Y. (1988) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/21/8/017 · Cited by 298
A Model for Diffusion in White Matter in the Brain
Sen, P. N., & Basser, P. J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.063016 · Cited by 266
Water diffusion, T2, and compartmentation in frog sciatic nerve
Peled, S., Cory, D. G., Raymond, S. A., Kirschner, D. A., & Jolesz, F. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<911::aid-mrm11>3.0.co;2-j · Cited by 191
Toosy, A. T. (2003) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.74.9.1250 · Cited by 182
Evaluation of Restricted Diffusion in Cylinders. Phosphocreatine in Rabbit Leg Muscle
Vangelderen, P., Despres, D., Vanzijl, P. C. M., & Moonen, C. T. W. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1038 · Cited by 178
Optimal acquisition orders of diffusion‐weighted MRI measurements
Cook, P. A., Symms, M. R., Boulby, P. A., & Alexander, D. C. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20905 · Cited by 131
Self-citationDiffusion imaging using stimulated echoes
Merboldt, K., Hänicke, W., & Frahm, J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190208 · Cited by 110
MR diffusion–“diffraction” phenomenon in multi-pulse-field-gradient experiments
Özarslan, E., & Basser, P. J. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.08.002 · Cited by 94
Avram, L., Assaf, Y., & Cohen, Y. (2004) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2004.03.020 · Cited by 82
Topgaard, D., & Söderman, O. (2003) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00626-4 · Cited by 50
Accuracy of $q$-Space Related Parameters in MRI: Simulations and Phantom Measurements
Lätt, J., Nilsson, M., Malmborg, C., Rosquist, H., Wirestam, R., St�hlberg, F., Topgaard, D., & Brockstedt, S. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.907278 · Cited by 42
Axon radius measurements in vivo from diffusion MRI: a feasibility study
Alexander, D. C. (2007) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2007.4409141 · Cited by 12
Self-citationMapping the parameter space of a T2-dependent model of water diffusion MR in brain tissue
Hansen, B., & Vestergaard‐Poulsen, P. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.04.012 · Cited by 9
Cited by
Functional and Effective Connectivity: A Review
Friston, K. J. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0008 · Cited by 3,415
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Self-citationJeurissen, B., Tournier, J.-D., Dhollander, T., Connelly, A., & Sijbers, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.061 · Cited by 1,454
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Self-citationInvestigating white matter fibre density and morphology using fixel-based analysis.
Raffelt, D. A., Tournier, J.-D., Smith, R. E., Vaughan, D. N., Jackson, G., Ridgway, G. R., & Connelly, A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.029 · Cited by 620
“Many DWI models assume that diffusion within axons is restricted in the radial orientation (Alexander, 2008; Assaf and Basser, 2005; Barazany et al., 2009; Jespersen et al., 2007; Lu et al., 2006; Raffelt et al., 2012b; Stanisz et al., 1997; Zhang et al., 2012), and that the exchange of water between the intra-axonal…”
Metadata
- Authors
- Alexander, D. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 60
- Issue
- 2
- Pages
- 439-448
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2127635814
- Cited by
- 331
- References
- 29
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.