Three‐dimensional high‐resolution magnetic resonance spectroscopic imaging for absolute quantification of 31P metabolites in human liver
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Liver dysfunction correlates with alterations of intracellular concentrations of 31 P metabolites. Localization and absolute quantification should help to trace regional hepatic metabolism. An improved protocol for the absolute quantification of 31 P metabolites in vivo in human liver was developed by employing three‐dimensional (3D) k‐space weighted spectroscopic imaging (MRSI) with B1‐insensitive adiabatic excitation. The protocol allowed for high spatial resolution of 17.8 ± 0.22 cm 3 in 34 min at 3 T. No pulse adjustment prior to MRSI measurement was necessary due to adiabatic excitation. The protocol geometry was identical for all measurements so that one calibration data set, acquired from phantom replacement measurement, was applied for all quantifications. The protocol was tested in 10 young, healthy volunteers, for whom 57 ± 7 spectra were quantified. Concentrations per liter of liver volume (reproducibilities) were 2.24 ± 0.10 mmol/L (1.8%) for phosphomonoesters (PME), 1.37 ± 0.07 mmol/L (7.9%) for inorganic phosphate (Pi), 11.40 ± 0.96 mmol/L (2.9%) for phosphodiesters (PDE), and 2.14 ± 0.10 mmol/L (1.6%) for adenosine triphosphate (ATP), respectively. Taken together, this approach provides fast, simple, and reproducible high‐resolution absolute quantification and detailed mapping of the spatial distribution of hepatic 31 P metabolites. This method allows for examination of regional deviations of energy metabolism in human liver diseases. Magn Reson Med 60:796–802, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schmid, A. I., Chmelík, M., Szendroedi, J., Krššák, M., Brehm, A., Moser, E., & Roden, M. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1207 · Cited by 67
Self-citation
Cited by
Liver ATP Synthesis Is Lower and Relates to Insulin Sensitivity in Patients With Type 2 Diabetes
Schmid, A. I., Szendroedi, J., Chmelik, M., Krššák, M., Moser, E., & Roden, M. (2011) · Diabetes Care · doi:10.2337/dc10-1076 · Cited by 212
Self-citationAbnormal Hepatic Energy Homeostasis in Type 2 Diabetes†
Szendroedi, J., Chmelik, M., Schmid, A. I., Nowotny, P., Brehm, A., Krssak, M., Moser, E., & Roden, M. (2009) · Hepatology · doi:10.1002/hep.23093 · Cited by 204
Self-citationEctopic lipids and organ function.
Szendroedi, J., & Roden, M. (2009) · Current Opinion in Lipidology · doi:10.1097/mol.0b013e328321b3a8 · Cited by 200
Self-citationAbdelmalek, M. F., Lazo, M., Horska, A., Bonekamp, S., Lipkin, E. W., Balasubramanyam, A., Bantle, J. P., Johnson, R. J., Diehl, A. M., & Clark, J. M. (2012) · Hepatology · doi:10.1002/hep.25741 · Cited by 190
“(31)P MRS allows for reproducible quantification and of phosphorus-containing metabolites.(36) Hepatic (31)P MRS detected in six resonances (i.”
Background
Metadata
- Authors
- Chmelík, M., Schmid, A. I., Gruber, S., Szendroedi, J., Krššák, M., Trattnig, S., Moser, E., & Roden, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-09-24
- Volume
- 60
- Issue
- 4
- Pages
- 796-802
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2052729160
- Cited by
- 53
- References
- 1
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three‐dimensional high‐resolution magnetic resonance spectroscopic imaging for absolute quantification of 31P metabolites in human liver. https://app.cochat.ai/papers/10.1002/mrm.21762
- The paper
- Chmelík, M., Schmid, A. I., Gruber, S., Szendroedi, J., Krššák, M., Trattnig, S., Moser, E., & Roden, M. (2008). Three‐dimensional high‐resolution magnetic resonance spectroscopic imaging for absolute quantification of 31P metabolites in human liver. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21762
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.