Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 474

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters

Stalder, A.F., Russe, M.F., Frydrychowicz, A., Bock, J., Hennig, J., Markl, M.·2008·Magnetic Resonance in Medicine

Abstract

Quantification of CINE phase contrast (PC)‐MRI data is a challenging task because of the limited spatiotemporal resolution and signal‐to‐noise ratio (SNR). The method presented in this work combines B‐spline interpolation and Green's theorem to provide optimized quantification of blood flow and vessel wall parameters. The B‐spline model provided optimal derivatives of the measured three‐directional blood velocities onto the vessel contour, as required for vectorial wall shear stress (WSS) computation. Eight planes distributed along the entire thoracic aorta were evaluated in a 19‐volunteer study using both high‐spatiotemporal‐resolution planar two‐dimensional (2D)‐CINE‐PC (∼1.4 × 1.4 mm 2/24.4 ms) and lower‐resolution 3D‐CINE‐PC (∼2.8 × 1.6 × 3 mm 3/48.6 ms) with three‐directional velocity encoding. Synthetic data, error propagation, and interindividual, intermodality, and interobserver variability were used to evaluate the reliability and reproducibility of the method. While the impact of MR measurement noise was only minor, the limited resolution of PC‐MRI introduced systematic WSS underestimations. In vivo data demonstrated close agreement for flow and WSS between 2D‐ and 3D‐CINE‐PC as well as observers, and confirmed the reliability of the method. WSS analysis along the aorta revealed the presence of a circumferential WSS component accounting for 10–20%. Initial results in a patient with atherosclerosis suggest the potential of the method for understanding the formation and progression of cardiovascular diseases. Magn Reson Med 60:1218–1231, 2008. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21778

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 474

Metadata

Authors
Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2008-10-27
Volume
60
Issue
5
Pages
1218-1231
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2068859764
Cited by
474
References
1
FWCI
13.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters. https://app.cochat.ai/papers/10.1002/mrm.21778
The paper
Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008). Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21778

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.