New diffusion phantoms dedicated to the study and validation of high‐angular‐resolution diffusion imaging (HARDI) models
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
We present new diffusion phantoms dedicated to the study and validation of high‐angular‐resolution diffusion imaging (HARDI) models. The phantom design permits the application of imaging parameters that are typically employed in studies of the human brain. The phantoms were made of small‐diameter acrylic fibers, chosen for their high hydrophobicity and flexibility that ensured good control of the phantom geometry. The polyurethane medium was filled under vacuum with an aqueous solution that was previously degassed, doped with gadolinium‐tetraazacyclododecanetetraacetic acid (Gd‐DOTA), and treated by ultrasonic waves. Two versions of such phantoms were manufactured and tested. The phantom's applicability was demonstrated on an analytical Q‐ball model. Numerical simulations were performed to assess the accuracy of the phantom. The phantom data will be made accessible to the community with the objective of analyzing various HARDI models. Magn Reson Med 60:1276–1283, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×
“During the last decade, diffusion-weighted (DW) imaging (DWI) has become an established technique for the diagnosis of ischemia (1) and investigations of the anatomical connectivity of the human brain (2).”
BackgroundTuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227 · cited 1×
“(24), compensating for the Eddy currents to the first order.”
BackgroundRegularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
Tournier, J.-D., Yeh, C.-H., Calamante, F., Cho, K.-H., Connelly, A., & Lin, C.-P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.002 · Cited by 593
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587 · cited 1×
“A graphical tool was developed to visualize the equators of the signal magnitude with a typical “peanut” shape (29).”
MethodMeasurement of translational displacement probabilities by NMR: An indicator of compartmentation
Cory, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140303 · Cited by 429
Özarslan, E., & Mareci, T. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10596 · Cited by 423
Persistent angular structure: new insights from diffusion magnetic resonance imaging data
Jansons, K. M., & Alexander, D. C. (2003) · Inverse Problems · doi:10.1088/0266-5611/19/5/303 · Cited by 304
NMR microscopy of dynamic displacements: k-space and q-space imaging
Callaghan, P. T., Eccles, C. D., & Xia, Y. (1988) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/21/8/017 · Cited by 298
Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo
Tofts, P. S., Lloyd, D., Clark, C. A., Barker, G. J., Parker, G. J. M., McConville, P., Baldock, C., & Pope, J. M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<368::aid-mrm8>3.0.co;2-b · Cited by 265 · cited 1×
“Several papers have proposed the use of agarose gel or alkanes (21,22).”
BackgroundAutomatic segmentation of thalamic nuclei from diffusion tensor magnetic resonance imaging
Wiegell, M. R., Tuch, D. S., Larsson, H. B. W., & Wedeen, V. J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00044-2 · Cited by 258
Characterizing non‐gaussian diffusion by using generalized diffusion tensors
Liu, C., Bammer, R., Acar, B., & Moseley, M. E. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20071 · Cited by 251
Lin, C.-P., Wedeen, V. J., Chen, J.-H., Yao, C., & Tseng, W.-Y. I. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00154-x · Cited by 225
Campbell, J. S. W., Siddiqi, K., Rymar, V. V., Sadikot, A. F., & Pike, G. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.014 · Cited by 177 · cited 1×
“Several diffusion phantom designs were proposed, based on fibrous vegetables (13), biological tissues (14), plastic capillaries (15–17), or textile fibers (18–20).”
BackgroundMaximum Entropy Spherical Deconvolution for Diffusion MRI
Alexander, D. C. (2005) · Lecture notes in computer science · doi:10.1007/11505730_7 · Cited by 153
Validation of q-ball imaging with a diffusion fibre-crossing phantom on a clinical scanner
Perrin, M., Poupon, C., Rieul, B., Leroux, P., Constantinesco, A., Mangin, J.-F., & LeBihan, D. (2005) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2005.1650 · Cited by 136
Self-citationAssaf, Y., & Cohen, Y. (1999) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199910)12:6<335::aid-nbm581>3.0.co;2-a · Cited by 101
Yanasak, N. E., & Allison, J. D. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.08.001 · Cited by 60
Lätt, J., Nilsson, M., Rydhög, A. S., Wirestam, R., Ståhlberg, F., & Brockstedt, S. (2007) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-007-0085-z · Cited by 52
A flexible hardware phantom for validation of diffusion imaging sequences
Fieremans, E., Delputte, S., Deblaere, K., Deene, Y. D., Truyens, B., D’Asseler, Y., Achten, E., Lemahieu, I. A., & Rik Van De Walle, B. (2005) · Ghent University Academic Bibliography (Ghent University) · Cited by 14
Using q-space Diffusion MRI for Structural Studies of a Biological Phantom at a 3T Clinical Scanner
Ryhög, A. (2007) · Lund University Publications Student Papers (Lund University) · Cited by 1
Cited by
Tractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,376
Tractography: Where Do We Go from Here?
Jbabdi, S., & Johansen-Berg, H. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0033 · Cited by 614
“Physical phantoms have been used to test low level models and tractography algorithms (Perrin et al., 2005; Poupon et al., 2008).”
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Quantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
“In particular, fibers lie in-plane because they have to be squeezed in between two solid dies to ensure high density and diffusion anisotropy approaching that of tissue (Poupon et al., 2008).”
BackgroundSelf-citationTowards quantitative connectivity analysis: reducing tractography biases
Girard, G., Whittingstall, K., Deriche, R., & Descoteaux, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.04.074 · Cited by 324
Metadata
- Authors
- Poupon, C., Rieul, B., Kezele, I., Perrin, M., Poupon, F., & Mangin, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-11-24
- Volume
- 60
- Issue
- 6
- Pages
- 1276-1283
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2092955737
- Cited by
- 197
- References
- 26
- FWCI
- 12.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.