Quantitative magnetization transfer measured pool‐size ratio reflects optic nerve myelin content in ex vivo mice
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Optic nerves from mice that have undergone retinal ischemia were examined using a newly implemented quantitative magnetization transfer (qMT) technique. Previously published results indicate that the optic nerve from retinal ischemia mice suffered significant axon degeneration without detectable myelin injury at 3 days after reperfusion. At this time point, we acquired ex vivo qMT parameters from both shiverer mice (which have nearly no myelin) and control mice that have undergone retinal ischemia, and these qMT measures were compared with diffusion tensor imaging (DTI) results. Our findings suggests that the qMT estimated ratio of the pool sizes of the macromolecular and free water protons reflected the different myelin contents in the optic nerves between the shiverer and control mice. This pool size ratio was specific to myelin content only and was not significantly affected by the presence of axon injury in mouse optic nerve 3 days after retinal ischemia. Magn Reson Med 61:364–371, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dysmyelination revealed through MRI as increased radial (but unchanged axial) diffusion of water
Song, S.-K., Sun, S.-W., Ramsbottom, M. J., Chang, C., Russell, J., & Cross, A. H. (2002) · NeuroImage · doi:10.1006/nimg.2002.1267 · Cited by 2,582 · cited 1×
“[5]–[7], were derived using software written in Matlab (MathWorks, Natick, MA, USA).”
MethodSelf-citationSong, S.-K., Sun, S.-W., Ju, W.-K., Lin, S.-J., Cross, A. H., & Neufeld, A. H. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.005 · Cited by 1,738
Self-citationDemyelination increases radial diffusivity in corpus callosum of mouse brain
Song, S.-K., Yoshino, J., Le, T. Q., Lin, S.-J., Sun, S.-W., Cross, A. H., & Armstrong, R. C. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.028 · Cited by 1,658
Self-citationApplications of diffusion‐weighted and diffusion tensor MRI to white matter diseases – a review
Horsfield, M. A., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.787 · Cited by 468
High field MRI correlates of myelin content and axonal density in multiple sclerosis
Mottershead, J. P., Schmierer, K., Clemence, M., Thornton, J. S., Scaravilli, F., Barker, G. J., Tofts, P. S., Newcombe, J., Cuzner, M. L., Ordidge, R. J., et al. (2003) · Journal of Neurology · doi:10.1007/s00415-003-0192-3 · Cited by 296
Beaulieu, C., & Allen, P. S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320506 · Cited by 240
Detecting axon damage in spinal cord from a mouse model of multiple sclerosis
Kim, J. H., Budde, M. D., Liang, H.-F., Klein, R. S., Russell, J. H., Cross, A. H., & Song, S.-K. (2006) · Neurobiology of Disease · doi:10.1016/j.nbd.2005.09.009 · Cited by 235 · cited 1×
“[4], where S is the diffusion-weighted signal, S0 is signal with diffusion weighting factor b 0, and n represents the encoding directions (28).”
BackgroundSelf-citationSun, S., Neil, J. J., & Song, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10605 · Cited by 231
Self-citationFormalin fixation alters water diffusion coefficient magnitude but not anisotropy in infarcted brain
Sun, S., Neil, J. J., Liang, H., He, Y. Y., Schmidt, R. E., Hsu, C. Y., & Song, S. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20488 · Cited by 204
Self-citationMR properties of excised neural tissue following experimentally induced inflammation
Stanisz, G. J., Webb, S., Munro, C. A., Pun, T., & Midha, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20008 · Cited by 138
Cited by
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2009) · Diffusion MRI · doi:10.1016/b978-0-12-374709-9.00006-7 · Cited by 217
Quantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination
Thiessen, J. D., Zhang, Y., Zhang, H., Wang, L., Buist, R., Del Bigio, M. R., Kong, J., Li, X., & Martin, M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2992 · Cited by 148
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2014) · Diffusion MRI · doi:10.1016/b978-0-12-396460-1.00008-1 · Cited by 66
Mole, J. P., Fasano, F., Evans, J., Sims, R., Hamilton, D. A., Kidd, E., & Metzler-Baddeley, C. (2020) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2020.06.014 · Cited by 20
Progressive axonopathy when oligodendrocytes lack the myelin protein CMTM5
Buscham, T. J., Eichel-Vogel, M. A., Steyer, A. M., Jahn, O., Strenzke, N., Dardawal, R., Memhave, T. R., Siems, S. B., Müller, C., Meschkat, M., et al. (2022) · eLife · doi:10.7554/elife.75523 · Cited by 18
Metadata
- Authors
- Ou, X., Sun, S., Liang, H., Song, S., & Gochberg, D. F.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-01-22
- Volume
- 61
- Issue
- 2
- Pages
- 364-371
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2042559621
- Cited by
- 76
- References
- 10
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative magnetization transfer measured pool‐size ratio reflects optic nerve myelin content in ex vivo mice. https://app.cochat.ai/papers/10.1002/mrm.21850
- The paper
- Ou, X., Sun, S., Liang, H., Song, S., & Gochberg, D. F. (2009). Quantitative magnetization transfer measured pool‐size ratio reflects optic nerve myelin content in ex vivo mice. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21850
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.