The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
The B‐matrix must be rotated when correcting for subject motion in DTI data
Abstract
To estimate diffusion tensor MRI (DTI) measures, such as fractional anisotropy and fiber orientation, reliably, a large number of diffusion‐encoded images is needed, preferably cardiac gated to reduce pulsation artifacts. However, the concomitant longer acquisition times increase the chances of subject motion adversely affecting the estimation of these measures. While correcting for motion artifacts improves the accuracy of DTI, an often overlooked step in realigning the images is to reorient the B‐matrix so that orientational information is correctly preserved. To the best of our knowledge, most research groups and software packages currently omit this reorientation step. Given the recent explosion of DTI applications including, for example, neurosurgical planning (in which errors can have drastic consequences), it is important to investigate the impact of neglecting to perform the B‐matrix reorientation. In this work, a systematic study to investigate the effect of neglecting to reorient the B‐matrix on DTI data during motion correction is presented. The consequences for diffusion fiber tractography are also discussed. Magn Reson Med, 61:1336–1349, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Spitzer, F. (1976) · Springer eBooks · doi:10.1007/978-1-4684-6257-9 · Cited by 2,080
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Self-citationJones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
Self-citation“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Self-citationComprehensive approach for correction of motion and distortion in diffusion‐weighted MRI
Rohde, G. K., Barnett, A. S., Basser, P. J., Marenco, S., & Pierpaoli, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10677 · Cited by 533
Farrell, J. A. D., Landman, B. A., Jones, C. K., Smith, S. A., Prince, J. L., van Zijl, P. C. M., & Mori, S. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21053 · Cited by 357
Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
Jezzard, P., Barnett, A. S., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390518 · Cited by 352
Skare, S., Hedehus, M., Moseley, M. E., & Li, T.-Q. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2209 · Cited by 297
Landman, B. A., Farrell, J. A. D., Jones, C. K., Smith, S. A., Prince, J. L., & Mori, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.056 · Cited by 285
Theoretical analysis of the effects of noise on diffusion tensor imaging
Anderson, A. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1315 · Cited by 280
A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPI
Andersson, J. L. R., & Skare, S. (2002) · NeuroImage · doi:10.1006/nimg.2001.1039 · Cited by 274
Kinoshita, M., Yamada, K., Hashimoto, N., Kato, A., Izumoto, S., Baba, T., Maruno, M., Nishimura, T., & Yoshimine, T. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.076 · Cited by 264
Clark, C. A., Barrick, T. R., Murphy, M. M., & Bell, B. A. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.022 · Cited by 261
A Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRI
Papadakis, N. G., Xing, D., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1673 · Cited by 203
Yu, C. S., Li, K. C., Xuan, Y., Ji, X. M., & Qin, W. (2005) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.04.010 · Cited by 203
Distortion correction and robust tensor estimation for MR diffusion imaging
Mangin, J.-F., Poupon, C., Clark, C., Le Bihan, D., & Bloch, I. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00079-8 · Cited by 194
Alexander, A. L., Tsuruda, J. S., & Parker, D. L. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380623 · Cited by 192
Bammer, R., Markl, M., Barnett, A., Acar, B., Alley, M. T., Pelc, N. J., Glover, G. H., & Moseley, M. E. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10545 · Cited by 173
Parametric and non-parametric statistical analysis of DT-MRI data
Pajevic, S., & Basser, P. J. (2003) · Journal of Magnetic Resonance · doi:10.1016/s1090-7807(02)00178-7 · Cited by 162
Jones, D. K. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.922191 · Cited by 161
Self-citationMinimal gradient encoding for robust estimation of diffusion anisotropy☆
Papadakis, N. G., Murrills, C. D., Hall, L. D., Huang, C. L.-H., & Carpenter, T. A. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00151-x · Cited by 149
Anisotropic noise propagation in diffusion tensor MRI sampling schemes
Batchelor, P. G., Atkinson, D., Hill, D., Calamante, F., & Connelly, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10491 · Cited by 139
Optimal acquisition orders of diffusion‐weighted MRI measurements
Cook, P. A., Symms, M. R., Boulby, P. A., & Alexander, D. C. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20905 · Cited by 131
A normal distribution for tensor-valued random variables: applications to diffusion tensor MRI
Basser, P. J., & Pajevic, S. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815059 · Cited by 126
The cortical motor threshold reflects microstructural properties of cerebral white matter
Klöppel, S., Bäumer, T., Kroeger, J., Koch, M., Büchel, C., Münchau, A. M., & Siebner, H. R. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.019 · Cited by 115
Geometric distortion correction of high‐resolution 3 T diffusion tensor brain images
Ardekani, S., & Sinha, U. S. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20651 · Cited by 83
Optimized diffusion gradient orientation schemes for corrupted clinical DTI data sets
Dubois, J., Poupon, C., Lethimonnier, F., & Bihan, D. L. (2006) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-006-0036-0 · Cited by 81
Gradient preemphasis calibration in diffusion-weighted echo-planar imaging
Papadakis, N. G., Martin, K. M., Pickard, J. D., Hall, L. D., Carpenter, T. A., & Huang, C. L.-H. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<616::aid-mrm16>3.0.co;2-t · Cited by 74
Jansen, J. F. A., Kooi, M. E., Kessels, A. G. H., Nicolay, K., & Backes, W. H. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000262757.10271.e5 · Cited by 58
Bastin, M. E., & Armitage, P. A. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00158-2 · Cited by 50
Aksoy, M., Liu, C., Moseley, M. E., & Bammer, R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21558 · Cited by 46
Diffusion tensor imaging at low SNR: nonmonotonic behaviors of tensor contrasts
Landman, B. A., Farrell, J. A. D., Huang, H., Prince, J. L., & Mori, S. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.034 · Cited by 46
Pasternak, O., Assaf, Y., Intrator, N., & Sochen, N. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.006 · Cited by 46
How does distortion correction correlate with anisotropic indices? A diffusion tensor imaging study
Kim, D., Park, H., KANG, K., Shin, Y., Kim, J., Moon, W., Chung, E.-C., Kim, I. Y., Kwon, J. S., & Kim, S. I. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.07.014 · Cited by 30
Nielsen, J., Ghugre, N., & Panigrahy, A. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.08.024 · Cited by 20
Basser (2000) · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationJeurissen, B., Tournier, J.-D., Dhollander, T., Connelly, A., & Sijbers, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.061 · Cited by 1,454
The hubs of the human connectome are generally implicated in the anatomy of brain disorders
Crossley, N. A., Mechelli, A., Scott, J., Carletti, F., Fox, P. T., McGuire, P., & Bullmore, E. T. (2014) · Brain · doi:10.1093/brain/awu132 · Cited by 1,166
Jeurissen, B., Leemans, A., Tournier, J., Jones, D. K., & Sijbers, J. (2013) · Human Brain Mapping · doi:10.1002/hbm.22099 · Cited by 1,088
Self-citationDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Self-citation
Metadata
- Authors
- Leemans, A., & Jones, D. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-03-24
- Volume
- 61
- Issue
- 6
- Pages
- 1336-1349
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2168844688
- Cited by
- 1,281
- References
- 38
- FWCI
- 32.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.