Mathematical description of q‐space in spherical coordinates: Exact q‐ball imaging
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Novel methodologies have been recently developed to characterize the microgeometry of neural tissues and porous structures via diffusion MRI data. In line with these previous works, this article provides a detailed mathematical description of q‐space in spherical coordinates that helps to highlight the differences and similarities between various related q‐space methodologies proposed to date such as q‐ball imaging (QBI), diffusion spectrum imaging (DSI), and diffusion orientation transform imaging (DOT). This formulation provides a direct relationship between the orientation distribution function (ODF) and the diffusion data without using any approximation. Under this relationship, the exact ODF can be computed by means of the Radon transform of the radial projection (in q‐space) of the diffusion MRI signal. This new methodology, termed exact q‐ball imaging (EQBI), was put into practice using an analytical ODF estimation in terms of spherical harmonics that allows obtaining model‐free and model‐based reconstructions. This work provides a new framework for combining information coming from diffusion data recorded on multiple spherical shells in q‐space (hybrid diffusion imaging encoding scheme), which is capable of mapping ODF to a high accuracy. This represents a step toward a more efficient development of diffusion MRI experiments for obtaining better ODF estimates. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Laplacian pyramid as a compact image code
Burt, P., & Adelson, E. (1983) · IEEE Transactions on Communications · doi:10.1109/tcom.1983.1095851 · Cited by 6,077
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635 · cited 4×
“Equations [9] and [10] are the angular and radial integrals respectively, where q and q̂ are the length and unit vector of q (i.”
BackgroundInfluentialHigh angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Cited by
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Accelerated microstructure imaging via Convex Optimization (AMICO) from diffusion MRI data
Daducci, A., Canales-Rodríguez, E. J., Zhang, H., Dyrby, T. B., Alexander, D. C., & Thiran, J.-P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.026 · Cited by 593
Self-citationPushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
“The technical challenges of developing the over-all system are discussed as well as results from SNR comparisons, ODF metrics and fiber tracking comparisons.”
MethodInfluentialTournier, J. ‐., Calamante, F., & Connelly, A. (2013) · NMR in Biomedicine · doi:10.1002/nbm.3017 · Cited by 403
“Although these results may be informative to some extent for diffusion spectrum imaging (19), particularly when implemented using a spherical coordinate framework (56), they do not provide an estimate of the highest b value required.”
BackgroundAganj, I., Lenglet, C., Sapiro, G., Yacoub, E., Ugurbil, K., & Harel, N. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22365 · Cited by 365
Modelling white matter with spherical deconvolution: How and why?
Dell'Acqua, F., & Tournier, J. ‐. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3945 · Cited by 206
Histological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
“The validation method of choice for most reconstruction algorithms (Aganj et al., 2010; Canales-Rodriguez et al., 2009; Descoteaux et al., 2007; Ozarslan et al., 2006; Tournier et al., 2007; Tuch et al., 2002), or comparison of algorithms (Alexander, 2005; Daducci et al.”
A Novel Sampling Theorem on the Sphere
McEwen, J. D., & Wiaux, Y. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2166394 · Cited by 172
Structural Abnormalities in Bipolar Euthymia: A Multicontrast Molecular Diffusion Imaging Study
Canales-Rodríguez, E. J., Pomarol-Clotet, E., Radua, J., Sarró, S., Alonso-Lana, S., Del Mar Bonnín, C., Goikolea, J. M., Maristany, T., García-Álvarez, R., Vieta, E., et al. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.09.027 · Cited by 72
Self-citation
Metadata
- Authors
- Canales‐Rodríguez, E. J., Melie‐García, L., & Iturria‐Medina, Y.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-03-24
- Volume
- 61
- Issue
- 6
- Pages
- 1350-1367
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2015251708
- Cited by
- 75
- References
- 10
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.