CoChat

A simulation environment for diffusion weighted MR experiments in complex media

Open access
Balls, Gregory T., Frank, Lawrence R. · 2009 · Magnetic Resonance in Medicine
Cited by 51

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Simulations of diffusion in neural tissues have traditionally been limited to analytical solutions, to grid‐based solvers, or to small‐scale Monte Carlo simulations. None of these approaches has had the capability to simulate realistic complex neural tissues on the scale of even a single voxel of reasonable (i.e., clinical) size. An approach is described that combines a Monte Carlo Brownian dynamics simulator capable of simulating diffusion in arbitrarily complex polygonal geometries with a signal integrator flexible enough to handle a variety of pulse sequences. Taken together, this package provides a complete and general simulation environment for diffusion MRI experiments. The simulator is validated against analytical solutions for unbounded diffusion and diffusion between parallel plates. Further results are shown for aligned fibers, varying packing density and permeability, and for crossing straight fibers. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22033

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Balls, G. T., & Frank, L. R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-06
Volume
62
Issue
3
Pages
771-778
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2066012778
Cited by
51
References
4
FWCI
1.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.