Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 529

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

B1 mapping by Bloch‐Siegert shift

Open access
Sacolick, Laura I., Wiesinger, Florian, Hancu, Ileana, Vogel, Mika W.·2010·Magnetic Resonance in Medicine

Abstract

A novel method for amplitude of radiofrequency field (B) mapping based on the Bloch‐Siegert shift is presented. Unlike conventionally applied double‐angle or other signal magnitude–based methods, it encodes the B1 information into signal phase, resulting in important advantages in terms of acquisition speed, accuracy, and robustness. The Bloch‐Siegert frequency shift is caused by irradiating with an off‐resonance radiofrequency pulse following conventional spin excitation. When applying the off‐resonance radiofrequency in the kilohertz range, spin nutation can be neglected and the primarily observed effect is a spin precession frequency shift. This shift is proportional to the square of the magnitude of B. Adding gradient image encoding following the off‐resonance pulse allows one to acquire spatially resolved B1 maps. The frequency shift from the Bloch‐Siegert effect gives a phase shift in the image that is proportional to B. The phase difference of two acquisitions, with the radiofrequency pulse applied at two frequencies symmetrically around the water resonance, is used to eliminate undesired off‐resonance effects due to amplitude of static field inhomogeneity and chemical shift. In vivo Bloch‐Siegert B1 mapping with 25 sec/slice is demonstrated to be quantitatively comparable to a 21‐min double‐angle map. As such, this method enables robust, high‐resolution B mapping in a clinically acceptable time frame. Magn Reson Med 63:1315–1322, 2010. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22357

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 529

Metadata

Authors
Sacolick, L. I., Wiesinger, F., Hancu, I., & Vogel, M. W.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2010-04-23
Volume
63
Issue
5
Pages
1315-1322
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2145535148
Cited by
529
References
12
FWCI
21.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: B1 mapping by Bloch‐Siegert shift. https://app.cochat.ai/papers/10.1002/mrm.22357
The paper
Sacolick, L. I., Wiesinger, F., Hancu, I., & Vogel, M. W. (2010). B1 mapping by Bloch‐Siegert shift. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22357

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.