CoChat

High‐resolution magnetization‐prepared 3D‐FLAIR imaging at 7.0 Tesla

Open access
Visser, Fredy, Zwanenburg, Jaco J. M., Hoogduin, Johannes M., Luijten, Peter R. · 2010 · Magnetic Resonance in Medicine
Cited by 114

The DOI matches its Crossref record.

Abstract

The aim of the present study is to develop a submillimeter volumetric (three‐dimensional) fluid‐attenuated inversion recovery sequence at 7T. Implementation of the fluid‐attenuated inversion recovery sequence is difficult as increased T1 weighting from prolonged T1 constants at 7T dominate the desired T2 contrast and yield suboptimal signal‐to‐noise ratio. Magnetization preparation was used to reduce T1 weighting and improve the T2 weighting. Also, practical challenges limit the implementation. Long refocusing trains with low flip angles were used to mitigate the specific absorption rate constraints. This resulted in a three‐dimensional magnetization preparation fluid‐attenuated inversion recovery sequence with 0.8 × 0.8 × 0.8 = 0.5 mm 3 resolution in a clinically acceptable scan time. The contrast‐to‐noise ratio between gray matter and white matter (contrast‐to‐noise ratio = signal‐to‐noise ratio [gray matter] − signal‐to‐noise ratio [white matter]) increased from 12 ± 9 without magnetization preparation to 28 ± 8 with magnetization preparation (n = 12). The signal‐to‐noise ratio increased for white matter by 13 ± 6% and for gray matter by 48 ± 15%. In conclusion, three‐dimensional fluid‐attenuated inversion recovery with high resolution and full brain coverage is feasible at 7T. Magnetization preparation reduces the T1 weighting, thereby improving the T2 weighted contrast and signal‐to‐noise ratio. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22397

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 114

Metadata

Authors
Visser, F., Zwanenburg, J. J. M., Hoogduin, J. M., & Luijten, P. R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2010-06-22
Volume
64
Issue
1
Pages
194-202
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2013025846
Cited by
114
References
0
FWCI
5.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐resolution magnetization‐prepared 3D‐FLAIR imaging at 7.0 Tesla. https://app.cochat.ai/papers/10.1002/mrm.22397
The paper
Visser, F., Zwanenburg, J. J. M., Hoogduin, J. M., & Luijten, P. R. (2010). High‐resolution magnetization‐prepared 3D‐FLAIR imaging at 7.0 Tesla. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22397

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.