The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout
Open accessAbstract
In MRI, the transmit radiofrequency field (B) inhomogeneity can lead to signal intensity variations and quantitative measurement errors. By independently mapping the local B variation, the radiofrequency‐related signal variations can be corrected for. In this study, we present a new fast B mapping method using a slice‐selective preconditioning radiofrequency pulse. Immediately after applying a slice‐selective preconditioning pulse, a turbo fast low‐angle‐shot imaging sequence with centric k‐space reordering is performed to capture the residual longitudinal magnetization left behind by the slice‐selective preconditioning pulse due to B variation. Compared to the reference double‐angle method, this method is considerably faster. Specifically, the total scan time for the double‐angle method is equal to the product of 2 (number of images), the number of phase‐encoding lines, and approximately 5 T1, whereas the slice‐selective preconditioning method takes approximately 5 T1. This method was validated in vitro and in vivo with a 3‐T whole‐body MRI system. The combined brain and pelvis B measurements showed excellent agreement and strong correlation with those by the double‐angle method (mean difference = 0.025; upper and lower 95% limits of agreement were −0.07 and 0.12; R = 0.93; P < 0.001). This fast B mapping method can be used for a variety of applications, including body imaging where fast imaging is desirable. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Nuclear Magnetic Resonance in One and Two Dimensions
Ernst, R. R., Bodenhausen, G., Wokaun, A., & Redfield, A. G. (1989) · Physics Today · doi:10.1063/1.2811094 · Cited by 4,201
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Principles of nuclear magnetic resonance in one and two dimensions
Bax, A. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90048-0 · Cited by 1,160
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Transmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421
Imaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Mapping of the Radiofrequency Field
Insko, E. K., & Bolinger, L. (1993) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1993.1133 · Cited by 323
Cited by
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
Metadata
- Authors
- Chung, S., Kim, D., Breton, E., & Axel, L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-05-10
- Volume
- 64
- Issue
- 2
- Pages
- 439-446
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2136778777
- Cited by
- 304
- References
- 22
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout. https://app.cochat.ai/papers/10.1002/mrm.22423
- The paper
- Chung, S., Kim, D., Breton, E., & Axel, L. (2010). Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22423
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.