The DOI matches its Crossref record.
1H NMR chemical shift selective (CHESS) imaging
Abstract
1 H NMR images of human or animal tissues reflect the spatial distribution of both water (H 2 O) and methylene (CH 2 ) proton resonance signals. There are several reasons for a separation of these contributions: (i) the large chemical shift dispersion in high magnetic fields (>or=1.5 T) which leads to an apparent spatial shift in 'composite' images between the superimposed H 2 O and CH 2 images; (ii) the evaluation and interpretation of proton H 2 O and CH 2 relaxation times from NMR images; and (iii) the physiological implications of 'water' and 'fat' distributions for medical diagnosis. The authors describe a chemical shift selective (CHESS) imaging technique which destroys the unwanted signal component by means of a selective 90 degrees excitation pulse and a subsequent magnetic field gradient ('homogeneity spoiling gradient') prior to imaging of the wanted component. The new method allows the creation of either a pure 'water' or 'fat' image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Haroon, E., Woolwine, B. J., Chen, X., Pace, T. W., Parekh, S., Spivey, J. R., Hu, X. P., & Miller, A. H. (2014) · Neuropsychopharmacology · doi:10.1038/npp.2014.25 · Cited by 154
Human brain: Proton diffusion MR spectroscopy
Posse, S., Cuenod, C. A., & Le Bihan, D. (1993) · Radiology · doi:10.1148/radiology.188.3.8351339 · Cited by 122
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10255 · Cited by 73
In Vivo Brain GSH: MRS Methods and Clinical Applications
Bottino, F., Lucignani, M., Napolitano, A., Dellepiane, F., Visconti, E., Rossi Espagnet, M. C., & Pasquini, L. (2021) · Antioxidants · doi:10.3390/antiox10091407 · Cited by 50
Metadata
- Authors
- Haase, A., Frahm, J., Hanicke, W., & Matthaei, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1985-04-01
- Volume
- 30
- Issue
- 4
- Pages
- 341-344
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2000229085
- Cited by
- 1,062
- References
- 0
- FWCI
- 8.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 1H NMR chemical shift selective (CHESS) imaging. https://app.cochat.ai/papers/10.1088/0031-9155/30/4/008
- The paper
- Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985). 1H NMR chemical shift selective (CHESS) imaging. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/30/4/008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.