The contribution of chemical exchange to MRI frequency shifts in brain tissue
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Recent high‐field MRI studies based on resonance frequency contrast have revealed brain structure with unprecedented detail. Although subtle magnetic susceptibility variations caused by iron and myelin seem to be important to this contrast, recent research on protein solutions suggests that chemical exchange between water and macromolecular protons may contribute substantially to the observed gray‐white matter frequency contrast. To investigate this, we performed spectroscopic MRI experiments at 14 T on samples of fixed human visual cortex and fresh pig brain. To allow direct observation of any exchange‐induced frequency shifts, these samples were soaked in reference chemicals (TSP and dioxane) that are assumed not to be involved in exchange. For both fresh and fixed tissues and with both reference chemicals, substantial negative exchange‐induced gray‐white matter frequency contrast (–6.3 to –13.5 ppb) was found, whereas intracortical contrast was negligible. The sign of the gray‐white matter exchange‐induced frequency difference was opposite to the overall gray‐white matter frequency difference observed in vivo. This suggests that exchange contributes to, but is not sufficient to explain, the frequency contrast in vivo and tissue susceptibility differences may have a greater contribution than previously thought. The exchange‐dependent contribution may report on tissue chemical composition and pH. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Lipid composition of the normal human brain: gray matter, white matter, and myelin
O'Brien, J. S., & Sampson, E. L. (1965) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)39619-x · Cited by 848
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast
Fukunaga, M., Li, T.-Q., van Gelderen, P., de Zwart, J. A., Shmueli, K., Yao, B., Lee, J., Maric, D., Aronova, M. A., Zhang, G., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911177107 · Cited by 408 · cited 3×
“Indeed, the primary source of the increased frequency in the stripe of Gennari has been shown to be iron (11,25), which might be expected to contribute more to susceptibility-induced contrast rather than that induced via chemical exchange.”
BackgroundResultSelf-citationAldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305 · cited 2×
“Prior to MRI, the formalinfixed tissue ( 1-cm thick) was washed with water (23) and then soaked for 7 days in a TSP solution (50% w/v in phosphate-buffered saline (PBS)).”
BackgroundMethodPostmortem MRI of human brain hemispheres: T 2 relaxation times during formaldehyde fixation
Dawe, R. J., Bennett, D. A., Schneider, J. A., Vasireddi, S. K., & Arfanakis, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21909 · Cited by 162 · cited 1×
“, via crosslinking of proteins (23,38)] and cause changes in the accessibility of exchangeable protons on molecular surfaces.”
Background
Cited by
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
“In addition, substances such as blood and contributions from calcium and trace elements, have also been found to affect the magnetic susceptibility of tissue (Mitsumori et al., 2009; Schweser et al., 2011; Sedlacik et al., 2007; Shmueli et al., 2011; Yamada et al., 1996).”
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Fiber orientation-dependent white matter contrast in gradient echo MRI
Wharton, S., & Bowtell, R. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211075109 · Cited by 316
Schweser, F., Sommer, K., Deistung, A., & Reichenbach, J. R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.067 · Cited by 241
“Several such effects have recently been proposed, including anisotropic magnetic susceptibility (Lee et al., 2010; Liu, 2010; Liu et al., 2012a), chemical proton exchange (Luo et al., 2010; Shmueli et al., 2011; Zhong et al., 2008), and a non-spherical Lorentzian cavity (He and Yablonskiy, 2009).”
BackgroundMagnetic susceptibility anisotropy of human brain in vivo and its molecular underpinnings
Li, W., Wu, B., Avram, A. V., & Liu, C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.038 · Cited by 210
“There are also growing evidence supporting the contribution of chemical exchange between macromolecules and mobile protons to the frequency shift contrast between gray and white matter (Luo et al., 2010; Shmueli et al., 2011; Zhong et al., 2008).”
Background
Metadata
- Authors
- Shmueli, K., Dodd, S. J., Li, T., & Duyn, J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-10-06
- Volume
- 65
- Issue
- 1
- Pages
- 35-43
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1999357437
- Cited by
- 75
- References
- 6
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.