CoChat

Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement

Open access
Yarnykh, Vasily L. · 2012 · Magnetic Resonance in Medicine
Cited by 162

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

A new method was developed for fast quantitative mapping of the macromolecular proton fraction defined within the two‐pool model of magnetization transfer. The method utilizes a single image with off‐resonance saturation, a reference image for data normalization, and T1, B0, and B1 maps with the total acquisition time ∼10 min for whole‐brain imaging. Macromolecular proton fraction maps are reconstructed by iterative solution of the matrix pulsed magnetization transfer equation with constrained values of other model parameters. Theoretical error model describing the variance due to noise and the bias due to deviations of constrained parameters from their actual values was formulated based on error propagation rules. The method was validated by comparison with the conventional multiparameter multipoint fit of the pulsed magnetization transfer model based on data from two healthy subjects and two multiple sclerosis patients. It was demonstrated theoretically and experimentally that accuracy of the method depends on the offset frequency and flip angle of the saturation pulse, and optimal ranges of these parameters are 4–7 kHz and 600°–900°, respectively. At optimal sampling conditions, the single‐point method enables <10% relative macromolecular proton fraction errors. Comparison with the multiparameter fitting method revealed very good agreement with no significant bias and limits of agreement around ±0.7%. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.23224

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

Metadata

Authors
Yarnykh, V. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-12-21
Volume
68
Issue
1
Pages
166-178
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2120654099
Cited by
162
References
38
FWCI
2.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.