Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
A new method was developed for fast quantitative mapping of the macromolecular proton fraction defined within the two‐pool model of magnetization transfer. The method utilizes a single image with off‐resonance saturation, a reference image for data normalization, and T1, B0, and B1 maps with the total acquisition time ∼10 min for whole‐brain imaging. Macromolecular proton fraction maps are reconstructed by iterative solution of the matrix pulsed magnetization transfer equation with constrained values of other model parameters. Theoretical error model describing the variance due to noise and the bias due to deviations of constrained parameters from their actual values was formulated based on error propagation rules. The method was validated by comparison with the conventional multiparameter multipoint fit of the pulsed magnetization transfer model based on data from two healthy subjects and two multiple sclerosis patients. It was demonstrated theoretically and experimentally that accuracy of the method depends on the offset frequency and flip angle of the saturation pulse, and optimal ranges of these parameters are 4–7 kHz and 600°–900°, respectively. At optimal sampling conditions, the single‐point method enables <10% relative macromolecular proton fraction errors. Comparison with the multiparameter fitting method revealed very good agreement with no significant bias and limits of agreement around ±0.7%. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482 · cited 7×
“Potential variability of these factors should be taken into account in the design of future clinical studies and may render the need for careful standardization of MPF mapping protocols and pulse sequences, especially in multicenter studies involving MRI equipment of different manufacturers and models.”
BackgroundInfluentialYarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026 · cited 3×
“In addition, the major sources of errors in the VFA method, such as B1 inhomogeneity and incomplete spoiling, were eliminated in this study by using actual flipangle imaging B1 correction (34) and the optimal radiofrequency and gradient spoiling scheme (35).”
MethodSelf-citationQuantitative interpretation of magnetization transfer
Henkelman, R. M., Huang, X., Xiang, Q., Stanisz, G. J., Swanson, S. D., & Bronskill, M. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290607 · Cited by 734 · cited 3×
“To separate the cross-relaxation parameters f and k from the longitudinal relaxation rates R 1 , an independent R1 measurement is used for the estimation of R F 1, assuming that either R1 is constant for all tissues (R B 1 1⁄4 1 s (1)) (4,5) or relaxation rates of the pools are equal (R1 1⁄4 R1 ) (8).”
BackgroundMethodDousset, V, Grossman, R. I., Ramer, K. N., Schnall, M. D., Young, L. H., Gonzalez-Scarano, F., Lavi, E., & Cohen, J. A. (1992) · Radiology · doi:10.1148/radiology.182.2.1732968 · Cited by 690 · cited 10×
“The most widely used example of this approach is MT ratio (MTR) (2), which characterizes MT by a relative decrease of the observed signal in the off-resonance saturation experi- ment.”
InfluentialIntroduction to System Sensitivity Theory
Frank, P. M., & Eslami, M. (1980) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1980.4308508 · Cited by 659 · cited 1×
“Sensitivity analysis (31,32) is a useful tool allowing semiquantitative comparison of effects of multiple input variables and parameters on the response variable in complex systems based on the formalism of partial derivatives.”
MethodSensitivity Analysis for Chemical Models
Saltelli, A., Ratto, M., Tarantola, S., & Campolongo, F. (2005) · Chemical Reviews · doi:10.1021/cr040659d · Cited by 639 · cited 1×
“Sensitivity analysis (31,32) is a useful tool allowing semiquantitative comparison of effects of multiple input variables and parameters on the response variable in complex systems based on the formalism of partial derivatives.”
MethodQuantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
Sled, J. G., & Pike, G. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1278 · Cited by 419
Helms, G., Dathe, H., Kallenberg, K., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21732 · Cited by 332 · cited 1×
“one MT pulse during pulse repetition time (TR) (3).”
BackgroundA Model for Magnetization Transfer in Tissues
Morrison, C., & Mark Henkelman, R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330404 · Cited by 305 · cited 2×
“To separate the cross-relaxation parameters f and k from the longitudinal relaxation rates R 1 , an independent R1 measurement is used for the estimation of R F 1, assuming that either R1 is constant for all tissues (R B 1 1⁄4 1 s (1)) (4,5) or relaxation rates of the pools are equal (R1 1⁄4 R1 ) (8).”
BackgroundMethodQuantitative magnetization transfer imaging in postmortem multiple sclerosis brain
Schmierer, K., Tozer, D. J., Scaravilli, F., Altmann, D. R., Barker, G. J., Tofts, P. S., & Miller, D. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20984 · Cited by 273
Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times
Ramani, A., Dalton, C., Miller, D. H., Tofts, P. S., & Barker, G. J. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00598-2 · Cited by 240
Yarnykh, V. L. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10120 · Cited by 173 · cited 8×
“To separate the cross-relaxation parameters f and k from the longitudinal relaxation rates R 1 , an independent R1 measurement is used for the estimation of R F 1, assuming that either R1 is constant for all tissues (R B 1 1⁄4 1 s (1)) (4,5) or relaxation rates of the pools are equal (R1 1⁄4 R1 ) (8).”
BackgroundMethodSelf-citationYarnykh, V. L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22394 · Cited by 170 · cited 2×
“In addition, the major sources of errors in the VFA method, such as B1 inhomogeneity and incomplete spoiling, were eliminated in this study by using actual flipangle imaging B1 correction (34) and the optimal radiofrequency and gradient spoiling scheme (35).”
MethodSelf-citationGochberg, D. F., & Gore, J. C. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21143 · Cited by 159
Quantitative magnetization transfer imaging using balanced SSFP
Gloor, M., Scheffler, K., & Bieri, O. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21705 · Cited by 155
Quantitative imaging of magnetization transfer using an inversion recovery sequence
Gochberg, D. F., & Gore, J. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10386 · Cited by 139
Underhill, H. R., Rostomily, R. C., Mikheev, A. M., Yuan, C., & Yarnykh, V. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.065 · Cited by 136
Self-citationCross-relaxation imaging reveals detailed anatomy of white matter fiber tracts in the human brain
Yarnykh, V. L., & Yuan, C. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.029 · Cited by 135 · cited 9×
“The latter assumption also renders equality of R 1 to the observed R1 (R F 1 1⁄4 R1 1⁄4 R1), if the observed R1 in the two-pool system is defined as the ‘‘slow’’ eigenvalue of the matrix RL (6,12).”
BackgroundMethodSelf-citationMR properties of excised neural tissue following experimentally induced demyelination
Odrobina, E. E., Lam, T. Y. J., Pun, T., Midha, R., & Stanisz, G. J. (2005) · NMR in Biomedicine · doi:10.1002/nbm.951 · Cited by 127
Quantitative magnetization transfer mapping of bound protons in multiple sclerosis
Tozer, D., Ramani, A., Barker, G. J., Davies, G. R., Miller, D. H., & Tofts, P. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10514 · Cited by 119
Volz, S., Nöth, U., Rotarska-Jagiela, A., & Deichmann, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.054 · Cited by 105
Modeling pulsed magnetization transfer
Portnoy, S., & Stanisz, G. J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21244 · Cited by 103 · cited 2×
“Second, it can be measured with reasonable accuracy by different techniques (20).”
BackgroundMethodOptimal acquisition schemes for in vivo quantitative magnetization transfer MRI
Cercignani, M., & Alexander, D. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21003 · Cited by 98 · cited 1×
“On the other hand, the two-pool model parameters determined by multipoint fitting techniques are relatively independent of measurement conditions, although some dependence may arise from the noise bias and a particular sampling scheme (19).”
BackgroundOu, X., Sun, S., Liang, H., Song, S., & Gochberg, D. F. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1358 · Cited by 90
Ou, X., Sun, S., Liang, H., Song, S., & Gochberg, D. F. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21850 · Cited by 76
Three-dimensional quantitative magnetisation transfer imaging of the human brain
Cercignani, M., Symms, M. R., Schmierer, K., Boulby, P. A., Tozer, D. J., Ron, M. A., Tofts, P. S., & Barker, G. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.031 · Cited by 75
Underhill, H. R., Yuan, C., & Yarnykh, V. L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.075 · Cited by 71
Self-citationHelms, G., Dathe, H., & Dechent, P. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22379 · Cited by 70 · cited 2×
“The effect of the flip angle a is also rather complex, because this parameter affects both SNR and the magnitude of the MT saturation effect (8,41).”
BackgroundA simple correction for B1 field errors in magnetization transfer ratio measurements
Samson, R. S., Wheeler‐Kingshott, C. A. M. G., Symms, M. R., Tozer, D. J., & Tofts, P. S. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.10.025 · Cited by 67 · cited 10×
“The most widely used example of this approach is MT ratio (MTR) (2), which characterizes MT by a relative decrease of the observed signal in the off-resonance saturation experi- ment.”
BackgroundInfluentialAssessment and correction of B1‐induced errors in magnetization transfer ratio measurements
Ropele, S., Filippi, M., Valsasina, P., Korteweg, T., Barkhof, F., Tofts, P. S., Samson, R. S., Miller, D. H., & Fazekas, F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20310 · Cited by 66 · cited 10×
“The most widely used example of this approach is MT ratio (MTR) (2), which characterizes MT by a relative decrease of the observed signal in the off-resonance saturation experi- ment.”
BackgroundInfluentialQuantitative imaging of magnetization transfer using multiple selective pulses
Gochberg, D. F., Kennan, R. P., Robson, M. D., & Gore, J. C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199905)41:5<1065::aid-mrm27>3.0.co;2-9 · Cited by 65 · cited 1×
“The latter assumption also renders equality of R 1 to the observed R1 (R F 1 1⁄4 R1 1⁄4 R1), if the observed R1 in the two-pool system is defined as the ‘‘slow’’ eigenvalue of the matrix RL (6,12).”
BackgroundMethod for quantitative imaging of the macromolecular 1H fraction in tissues
Ropele, S., Seifert, T., Enzinger, C., & Fazekas, F. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10427 · Cited by 64 · cited 2×
“(29) requires single-slice two-dimensional acquisition, which translates into a long scan time if whole-brain coverage is needed.”
BackgroundMethodMT effects and T1 quantification in single‐slice spoiled gradient echo imaging
Ou, X., & Gochberg, D. F. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21550 · Cited by 61 · cited 2×
“This bias may result in relative R1 errors on the order of MPF at short TR typically used in VFA measurements (42).”
BackgroundRausch, M., Tofts, P. S., Lervik, P., Walmsley, A. R., Mir, A. K., Schubart, A., & Seabrook, T. J. (2008) · Multiple Sclerosis Journal · doi:10.1177/1352458508096006 · Cited by 48
Fast bound pool fraction mapping using stimulated echoes
Soellinger, M., Langkammer, C., Seifert‐Held, T., Fazekas, F., & Ropele, S. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22846 · Cited by 26 · cited 3×
“The recent stimulated-echo technique (30) achieves improved time efficiency by using single-shot echo-planar acquisition, which makes it prone to artifacts associated with the readout sequence and imposes limitations in spatial resolution.”
BackgroundMethodLow power method for estimating the magnetization transfer bound‐pool macromolecular fraction
Lee, R. R., & Dagher, A. P. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070521 · Cited by 25 · cited 1×
“Lee and Dagher (28) introduced several simplifications into the stationary two-pool model formalism (4) and demonstrated that MPF can be estimated from a single continuous-wave saturation experiment with off-resonance irradiation applied at low power and a complimentary T1 measurement, assuming that cross-relaxation i…”
BackgroundNonbalanced SSFP‐based quantitative magnetization transfer imaging
Gloor, M., Scheffler, K., & Bieri, O. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22331 · Cited by 25
Cited by
Petrie, E. C., Cross, D. J., Yarnykh, V. L., Richards, T., Martin, N. M., Pagulayan, K., Hoff, D., Hart, K., Mayer, C., Tarabochia, M., et al. (2014) · Journal of Neurotrauma · doi:10.1089/neu.2013.2952 · Cited by 211
“During the second step, the pulsed magnetization transfer matrix equation 13,42 was iteratively solved by the Gauss-Newton method with B0 and B1 correction and standardized constraints for nonadjustable two-pool model parameters 14 to yield MPF maps.”
Self-citationAn interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Spatio-Temporal Patterns of Demyelination and Remyelination in the Cuprizone Mouse Model
Tagge, I., O’Connor, A., Chaudhary, P., Pollaro, J., Berlow, Y., Chalupsky, M., Bourdette, D., Woltjer, R., Johnson, M., & Rooney, W. (2016) · PLOS ONE · doi:10.1371/journal.pone.0152480 · Cited by 81
Metadata
- Authors
- Yarnykh, V. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-12-21
- Volume
- 68
- Issue
- 1
- Pages
- 166-178
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2120654099
- Cited by
- 162
- References
- 38
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.