Investigating the magnetic susceptibility properties of fresh human blood for noninvasive oxygen saturation quantification
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Quantification of blood oxygen saturation on the basis of a measurement of its magnetic susceptibility demands knowledge of the difference in volume susceptibility between fully oxygenated and fully deoxygenated blood (Δχ do). However, two very different values of Δχ do are currently in use. In this work we measured Δχ do as well as the susceptibility of oxygenated blood relative to water, Δχ oxy, by MR susceptometry in samples of freshly drawn human blood oxygenated to various levels, from 6 to 98% as determined by blood gas analysis. Regression analysis yielded 0.273 ± 0.006 and −0.008 ± 0.003 ppm (cgs) respectively, for Δχ do and Δχ oxy, in excellent agreement with previous work by Spees et al. (Magn Reson Med 2001;45:533–542). Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Red blood cell magnetophoresis
Zborowski, M., Ostera, G. R., Moore, L. R., Milliron, S., Chalmers, J. J., & Schechter, A. N. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75069-3 · Cited by 260 · cited 1×
“(22) on RBC magnetophoretic motilities yielded a value of 0.”
Background
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Cerebral Oxygen Metabolism in Neonates with Congenital Heart Disease Quantified by MRI and Optics
Jain, V., Buckley, E. M., Licht, D. J., Lynch, J. M., Schwab, P. J., Naim, M. Y., Lavin, N. A., Nicolson, S. C., Montenegro, L. M., Yodh, A. G., et al. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.214 · Cited by 198
Self-citationExploring early human brain development with structural and physiological neuroimaging
Vasung, L., Abaci Turk, E., Ferradal, S. L., Sutin, J., Stout, J. N., Ahtam, B., Lin, P.-Y., & Grant, P. E. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.041 · Cited by 177
Metadata
- Authors
- Jain, V., Abdulmalik, O., Propert, K. J., & Wehrli, F. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-12-08
- Volume
- 68
- Issue
- 3
- Pages
- 863-867
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1997556854
- Cited by
- 113
- References
- 4
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.