High‐resolution functional MRI at 3 T: 3D/2D echo‐planar imaging with optimized physiological noise correction
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
High‐resolution functional MRI (fMRI) offers unique possibilities for studying human functional neuroanatomy. Although high‐resolution fMRI has proven its potential at 7 T, most fMRI studies are still performed at rather low spatial resolution at 3 T. We optimized and compared single‐shot two‐dimensional echo‐planar imaging (EPI) and multishot three‐dimensional EPI high‐resolution fMRI protocols. We extended image‐based physiological noise correction from two‐dimensional EPI to multishot three‐dimensional EPI. The functional sensitivity of both acquisition schemes was assessed in a visual fMRI experiment. The physiological noise correction increased the sensitivity significantly, can be easily applied, and requires simple recordings of pulse and respiration only. The combination of three‐dimensional EPI with physiological noise correction provides exceptional sensitivity for 1.5 mm high‐resolution fMRI at 3 T, increasing the temporal signal‐to‐noise ratio by more than 25% compared to two‐dimensional EPI. Magn Reson Med, 2013. © 2012 The Authors. Magnetic Resonance in Medicine Published by Wiley Periodicals, Inc. on behalf of International Society of Medicine in Resonance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296 · cited 2×
“Multiplexed 2D EPI is an innovative approach to speeding up acquisition by combining multiband excitation and simultaneous echo refocusing, but it has not been applied to high-resolution fMRI at 3 T (9).”
Method
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Network activity underlying the illusory self‐attribution of a dummy arm
Limanowski, J., & Blankenburg, F. (2015) · Human Brain Mapping · doi:10.1002/hbm.22770 · Cited by 101
Action-specific value signals in reward-related regions of the human brain
FitzGerald, T. H. B., Friston, K. J., & Dolan, R. J. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3254-12.2012 · Cited by 68
Metadata
- Authors
- Lutti, A., Thomas, D. L., Hutton, C., & Weiskopf, N.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-07-20
- Volume
- 69
- Issue
- 6
- Pages
- 1657-1664
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2130994963
- Cited by
- 87
- References
- 2
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐resolution functional MRI at 3 T: 3D/2D echo‐planar imaging with optimized physiological noise correction. https://app.cochat.ai/papers/10.1002/mrm.24398
- The paper
- Lutti, A., Thomas, D. L., Hutton, C., & Weiskopf, N. (2013). High‐resolution functional MRI at 3 T: 3D/2D echo‐planar imaging with optimized physiological noise correction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24398
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.