Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Method for high‐resolution imaging of creatine in vivo using chemical exchange saturation transfer

Open access
Kogan, Feliks, Haris, Mohammad, Singh, Anup, Cai, Kejia, Debrosse, Catherine, Nanga, Ravi Prakash Reddy, Hariharan, Hari, Reddy, Ravinder · 2014 · Magnetic Resonance in Medicine

Abstract

Purpose: To develop a chemical exchange saturation transfer (CEST)‐based technique to measure free creatine (Cr) and to validate the technique by measuring the distribution of Cr in muscle with high spatial resolution before and after exercise. Methods: Phantom studies were performed to determine contributions from other Cr kinase metabolites to the CEST effect from Cr (CrCEST). CEST, T2, magnetization transfer ratio and 31 P magnetic resonance spectroscopy acquisitions of the lower leg were performed before and after plantar flexion exercise on a 7T whole‐body magnetic resonance scanner on healthy volunteers. Results: Phantom studies demonstrated that while Cr exhibited significant CEST effect there were no appreciable contributions from other metabolites. In healthy human subjects, following mild plantar flexion exercise, increases in the CEST effect from Cr were observed, which recovered exponentially back to baseline. This technique exhibited good spatial resolution and was able to differentiate differences in muscle utilization among subjects. The CEST effect from Cr results were compared with 31 P magnetic resonance spectroscopy results showing good agreement in the Cr and phosphocreatine recovery kinetics. Conclusion: Demonstrated a CEST‐based technique to measure free Cr changes in in vivo muscle. The CEST effect from Cr imaging can spatially map changes in Cr concentration in muscle following mild exercise. This may serve as a tool for the diagnosis and treatment of various disorders affecting muscle. Magn Reson Med 71:164–172, 2014. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24641

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 174

Metadata

Authors
Kogan, F., Haris, M., Singh, A., Cai, K., Debrosse, C., Nanga, R. P. R., Hariharan, H., & Reddy, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2013-02-14
Volume
71
Issue
1
Pages
164-172
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1777733060
Cited by
174
References
1
FWCI
14.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Method for high‐resolution imaging of creatine in vivo using chemical exchange saturation transfer. https://app.cochat.ai/papers/10.1002/mrm.24641
The paper
Kogan, F., Haris, M., Singh, A., Cai, K., Debrosse, C., Nanga, R. P. R., Hariharan, H., & Reddy, R. (2014). Method for high‐resolution imaging of creatine in vivo using chemical exchange saturation transfer. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24641

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.