The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Method for high‐resolution imaging of creatine in vivo using chemical exchange saturation transfer
Open accessAbstract
Purpose: To develop a chemical exchange saturation transfer (CEST)‐based technique to measure free creatine (Cr) and to validate the technique by measuring the distribution of Cr in muscle with high spatial resolution before and after exercise. Methods: Phantom studies were performed to determine contributions from other Cr kinase metabolites to the CEST effect from Cr (CrCEST). CEST, T2, magnetization transfer ratio and 31 P magnetic resonance spectroscopy acquisitions of the lower leg were performed before and after plantar flexion exercise on a 7T whole‐body magnetic resonance scanner on healthy volunteers. Results: Phantom studies demonstrated that while Cr exhibited significant CEST effect there were no appreciable contributions from other metabolites. In healthy human subjects, following mild plantar flexion exercise, increases in the CEST effect from Cr were observed, which recovered exponentially back to baseline. This technique exhibited good spatial resolution and was able to differentiate differences in muscle utilization among subjects. The CEST effect from Cr results were compared with 31 P magnetic resonance spectroscopy results showing good agreement in the Cr and phosphocreatine recovery kinetics. Conclusion: Demonstrated a CEST‐based technique to measure free Cr changes in in vivo muscle. The CEST effect from Cr imaging can spatially map changes in Cr concentration in muscle following mild exercise. This may serve as a tool for the diagnosis and treatment of various disorders affecting muscle. Magn Reson Med 71:164–172, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biochemistry of exercise-induced metabolic acidosis
Robergs, R. A., Ghiasvand, F., & Parker, D. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00114.2004 · Cited by 1,304
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Zaiss, M., & Bachert, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/r221 · Cited by 323
Zaiss, M., Xu, J., Goerke, S., Khan, I. S., Singer, R. J., Gore, J. C., Gochberg, D. F., & Bachert, P. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3054 · Cited by 316
Mitochondrial Dysfunction in Heart Failure With Preserved Ejection Fraction
Kumar, A. A., Kelly, D. P., & Chirinos, J. A. (2019) · Circulation · doi:10.1161/circulationaha.118.036259 · Cited by 298
Clinical applications of chemical exchange saturation transfer (CEST) MRI
Jones, K. M., Pollard, A. C., & Pagel, M. D. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25838 · Cited by 287
Metadata
- Authors
- Kogan, F., Haris, M., Singh, A., Cai, K., Debrosse, C., Nanga, R. P. R., Hariharan, H., & Reddy, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-02-14
- Volume
- 71
- Issue
- 1
- Pages
- 164-172
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1777733060
- Cited by
- 174
- References
- 1
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.