The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Inverse Z‐spectrum analysis for spillover‐, MT‐, and T1‐corrected steady‐state pulsed CEST‐MRI – application to pH‐weighted MRI of acute stroke
Open accessAbstract
Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects, such as direct water proton saturation (spillover) and semi‐solid macromolecular magnetization transfer (MT). This leads to unwanted T2 and MT signal contributions that lessen the CEST signal specificity to the underlying biochemical exchange processes. A spillover correction is of special interest for clinical static field strengths and protons resonating near the water peak. This is the case for all endogenous CEST agents, such as amide proton transfer, –OH‐CEST of glycosaminoglycans, glucose or myo‐inositol, and amine exchange of creatine or glutamate. All CEST effects also appear to be scaled by the T1 relaxation time of water, as they are mediated by the water pool. This forms the motivation for simple metrics that correct the CEST signal. Based on eigenspace theory, we propose a novel magnetization transfer ratio (MTRR ex), employing the inverse Z‐spectrum, which eliminates spillover and semi‐solid MT effects. This metric can be simply related to Rex, the exchange‐dependent relaxation rate in the rotating frame, and ka, the inherent exchange rate. Furthermore, it can be scaled by the duty cycle, allowing for simple translation to clinical protocols. For verification, the amine proton exchange of creatine in solutions with different agar concentrations was studied experimentally at a clinical field strength of 3 T, where spillover effects are large. We demonstrate that spillover can be properly corrected and that quantitative evaluation of pH and creatine concentration is possible. This proves that MTRR ex is a quantitative and biophysically specific CEST‐MRI metric. Applied to acute stroke induced in rat brain, the corrected CEST signal shows significantly higher contrast between the stroke area and normal tissue, as well as less B1 dependence, than conventional approaches. Copyright © 2014 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Quantitative interpretation of magnetization transfer
Henkelman, R. M., Huang, X., Xiang, Q., Stanisz, G. J., Swanson, S. D., & Bronskill, M. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290607 · Cited by 734
Kim, M., Gillen, J., Landman, B. A., Zhou, J., & van Zijl, P. C. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21873 · Cited by 691
Magnetic resonance imaging of glutamate
Cai, K., Haris, M., Singh, A., Kogan, F., Greenberg, J. H., Hariharan, H., Detre, J. A., & Reddy, R. (2012) · Nature Medicine · doi:10.1038/nm.2615 · Cited by 660
Ling, W., Regatte, R. R., Navon, G., & Jerschow, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707666105 · Cited by 533
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Woessner, D. E., Zhang, S., Merritt, M. E., & Sherry, A. D. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20408 · Cited by 375
Liu, K., Mori, S., Takahashi, H. K., Tomono, Y., Wake, H., Kanke, T., Sato, Y., Hiraga, N., Adachi, N., Yoshino, T., et al. (2007) · The FASEB Journal · doi:10.1096/fj.07-8770com · Cited by 366
Cited by
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationClinical applications of chemical exchange saturation transfer (CEST) MRI
Jones, K. M., Pollard, A. C., & Pagel, M. D. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25838 · Cited by 287
A multiparametric analysis of white matter maturation during late childhood and adolescence
Geeraert, B. L., Lebel, R. M., & Lebel, C. (2019) · Human Brain Mapping · doi:10.1002/hbm.24706 · Cited by 69
Lee, D.-W., Heo, H., Woo, C.-W., Woo, D.-C., Kim, J.-K., Kim, K.-W., & Lee, D.-H. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21249468 · Cited by 9
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Metadata
- Authors
- Zaiss, M., Xu, J., Goerke, S., Khan, I. S., Singer, R. J., Gore, J. C., Gochberg, D. F., & Bachert, P.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2014-01-03
- Volume
- 27
- Issue
- 3
- Pages
- 240-252
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1482675544
- Cited by
- 316
- References
- 38
- FWCI
- 17.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inverse Z‐spectrum analysis for spillover‐, MT‐, and T1‐corrected steady‐state pulsed CEST‐MRI – application to pH‐weighted MRI of acute stroke. https://app.cochat.ai/papers/10.1002/nbm.3054
- The paper
- Zaiss, M., Xu, J., Goerke, S., Khan, I. S., Singer, R. J., Gore, J. C., Gochberg, D. F., & Bachert, P. (2014). Inverse Z‐spectrum analysis for spillover‐, MT‐, and T1‐corrected steady‐state pulsed CEST‐MRI – application to pH‐weighted MRI of acute stroke. NMR in Biomedicine. https://doi.org/10.1002/nbm.3054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.