CoChat

Multiband accelerated spin‐echo echo planar imaging with reduced peak RF power using time‐shifted RF pulses

Open access
Auerbach, Edward J., Xu, Junqian, Yacoub, Essa, Moeller, Steen, Uğurbil, Kâmil · 2013 · Magnetic Resonance in Medicine
Cited by 144

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Purpose: To evaluate an alternative method for generating multibanded radiofrequency (RF) pulses for use in multiband slice‐accelerated imaging with slice‐GRAPPA unaliasing, substantially reducing the required peak power without bandwidth compromises. This allows much higher accelerations for spin‐echo methods such as SE‐fMRI and diffusion‐weighted MRI where multibanded slice acceleration has been limited by available peak power. Theory and Methods: Multibanded “time‐shifted” RF pulses were generated by inserting temporal shifts between the applications of RF energy for individual bands, avoiding worst‐case constructive interferences. Slice profiles and images in phantoms and human subjects were acquired at 3 T. Results: For typical sinc pulses, time‐shifted multibanded RF pulses were generated with little increase in required peak power compared to single‐banded pulses. Slice profile quality was improved by allowing for higher pulse bandwidths, and image quality was improved by allowing for optimum flip angles to be achieved. Conclusion: A simple approach has been demonstrated that significantly alleviates the restrictions imposed on achievable slice acceleration factors in multiband spin‐echo imaging due to the power requirements of multibanded RF pulses. This solution will allow for increased accelerations in diffusion‐weighted MRI applications where data acquisition times are normally very long and the ability to accelerate is extremely valuable. Magn Reson Med 69:1261–1267, 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24719

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 144

Metadata

Authors
Auerbach, E. J., Xu, J., Yacoub, E., Moeller, S., & Uğurbil, K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2013-03-06
Volume
69
Issue
5
Pages
1261-1267
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2007294293
Cited by
144
References
6
FWCI
8.56
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiband accelerated spin‐echo echo planar imaging with reduced peak RF power using time‐shifted RF pulses. https://app.cochat.ai/papers/10.1002/mrm.24719
The paper
Auerbach, E. J., Xu, J., Yacoub, E., Moeller, S., & Uğurbil, K. (2013). Multiband accelerated spin‐echo echo planar imaging with reduced peak RF power using time‐shifted RF pulses. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24719

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.