The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Design of multishell sampling schemes with uniform coverage in diffusion MRI
Open accessAbstract
Purpose: In diffusion MRI, a technique known as diffusion spectrum imaging reconstructs the propagator with a discrete Fourier transform, from a Cartesian sampling of the diffusion signal. Alternatively, it is possible to directly reconstruct the orientation distribution function in q‐ball imaging, providing so‐called high angular resolution diffusion imaging. In between these two techniques, acquisitions on several spheres in q‐space offer an interesting trade‐off between the angular resolution and the radial information gathered in diffusion MRI. A careful design is central in the success of multishell acquisition and reconstruction techniques. Methods: The design of acquisition in multishell is still an open and active field of research, however. In this work, we provide a general method to design multishell acquisition with uniform angular coverage. This method is based on a generalization of electrostatic repulsion to multishell. Results: We evaluate the impact of our method using simulations, on the angular resolution in one and two bundles of fiber configurations. Compared to more commonly used radial sampling, we show that our method improves the angular resolution, as well as fiber crossing discrimination. Discussion: We propose a novel method to design sampling schemes with optimal angular coverage and show the positive impact on angular resolution in diffusion MRI. Magn Reson Med 69:1534–1540, 2013. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Regularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
(2009) · doi:10.1016/b978-0-12-374709-9.x0001-6 · Cited by 686
Aganj, I., Lenglet, C., Sapiro, G., Yacoub, E., Ugurbil, K., & Harel, N. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22365 · Cited by 365
Self-citationThe spatial mapping of translational diffusion coefficients by the NMR imaging technique
Taylor, D. G., & Bushell, M. C. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/009 · Cited by 344
Cited by
Jeurissen, B., Tournier, J.-D., Dhollander, T., Connelly, A., & Sijbers, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.061 · Cited by 1,454
Dipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
“…Sherbrooke, QC, Canada 2 MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK 3 Henry H. Wheeler, Jr. Brain Imaging Center, University of California, Berkeley, CA, USA 4 Department of Neurology and Graduate Group in Bioengineering, University of California, San Francisco,…”
BackgroundInfluentialUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationMulti-compartment microscopic diffusion imaging
Kaden, E., Kelm, N. D., Carson, R. P., Does, M. D., & Alexander, D. C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.002 · Cited by 345
MGH–USC Human Connectome Project datasets with ultra-high b-value diffusion MRI
Fan, Q., Witzel, T., Nummenmaa, A., Van Dijk, K. R. A., Van Horn, J. D., Drews, M. K., Somerville, L. H., Sheridan, M. A., Santillana, R. M., Snyder, J., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.075 · Cited by 254
Histological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
“A gradient table of 100 uniformly distributed directions (Caruyer et al., 2013) was used to acquired 100 diffusion-weighted volumes with four additional image volumes collected at b 1⁄4 0.”
Can increased spatial resolution solve the crossing fiber problem for diffusion MRI?
Schilling, K., Gao, Y., Janve, V., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3787 · Cited by 102
Diffusion models reveal white matter microstructural changes with ageing, pathology and cognition
Raghavan, S., Reid, R. I., Przybelski, S. A., Lesnick, T. G., Graff-Radford, J., Schwarz, C. G., Knopman, D. S., Mielke, M. M., Machulda, M. M., Petersen, R. C., et al. (2021) · Brain Communications · doi:10.1093/braincomms/fcab106 · Cited by 79
Aydogan, D. B., Jacobs, R., Dulawa, S., Thompson, S. L., Francois, M. C., Toga, A. W., Dong, H., Knowles, J. A., & Shi, Y. (2018) · Brain Structure and Function · doi:10.1007/s00429-018-1663-8 · Cited by 72
Crombe, A., Planche, V., Raffard, G., Bourel, J., Dubourdieu, N., Panatier, A., Fukutomi, H., Dousset, V., Oliet, S., Hiba, B., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.061 · Cited by 49
Crombé, A., Nicolas, R., Richard, N., Tourdias, T., & Hiba, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-15511-0 · Cited by 13
Metadata
- Authors
- Caruyer, E., Lenglet, C., Sapiro, G., & Deriche, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-04-26
- Volume
- 69
- Issue
- 6
- Pages
- 1534-1540
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2077203280
- Cited by
- 302
- References
- 33
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.