Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 285

The DOI matches its Crossref record.

Frequency and phase drift correction of magnetic resonance spectroscopy data by spectral registration in the time domain

Open access
Near, Jamie, Edden, Richard, Evans, C. John, Paquin, Raphaël, Harris, Ashley, Jezzard, Peter·2015·Magnetic Resonance in Medicine

Abstract

Purpose: Frequency and phase drifts are a common problem in the acquisition of in vivo magnetic resonance spectroscopy (MRS) data. If not accounted for, frequency and phase drifts will result in artifactual broadening of spectral peaks, distortion of spectral lineshapes, and a reduction in signal‐to‐noise ratio (SNR). We present herein a new method for estimating and correcting frequency and phase drifts in in vivo MRS data. Methods: We used a simple method of fitting each spectral average to a reference scan (often the first average in the series) in the time domain through adjustment of frequency and phase terms. Due to the similarity with image registration, this method is referred to as “spectral registration.” Using simulated data with known frequency and phase drifts, the performance of spectral registration was compared with two existing methods at various SNR levels. Results: Spectral registration performed well in comparison with the other methods tested in terms of both frequency and phase drift estimation. Conclusions: Spectral registration provides an effective method for frequency and phase drift correction. It does not involve the collection of navigator echoes, and does not rely on any specific resonances, such as residual water or creatine, making it highly versatile. Magn Reson Med 73:44–50, 2015. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.25094

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 285

Metadata

Authors
Near, J., Edden, R., Evans, C. J., Paquin, R., Harris, A., & Jezzard, P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2014-01-16
Volume
73
Issue
1
Pages
44-50
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1639707408
Cited by
285
References
0
FWCI
15.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Frequency and phase drift correction of magnetic resonance spectroscopy data by spectral registration in the time domain. https://app.cochat.ai/papers/10.1002/mrm.25094
The paper
Near, J., Edden, R., Evans, C. J., Paquin, R., Harris, A., & Jezzard, P. (2015). Frequency and phase drift correction of magnetic resonance spectroscopy data by spectral registration in the time domain. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25094

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.