Abstract

Purpose: Multicomponent driven equilibrium single pulse observation of T 1 and T 2(mcDESPOT) is an alternative to established multiecho T 2‐based approaches for quantifying myelin water fraction, affording increased volumetric coverage and spatial resolution. A concern with mcDESPOT, however, is the large number of model parameters that must be estimated, which may lead to nonunique solutions and sensitivity to fitting constraints. Here we explore mcDESPOT performance under different experimental conditions to better understand the method's sensitivity and reliability. Methods: To obtain parameter estimates, mcDESPOT uses a stochastic region contraction (SRC) approach to iteratively contract a predefined solution search‐space around a global optimum. The sensitivity of mcDESPOT estimates to SRC boundary conditions, and tissue parameters, was examined using numerical phantoms and acquired in vivo human data. Results: The SRC approach is described and shown to return robust myelin water estimates in both numerical phantoms and in vivo data under a range of experimental conditions. However, care must be taken in choosing the initial SRC boundary conditions, ensuring they are broad enough to encompass the “true” solution. Conclusion: Results suggest that under the range of conditions examined, mcDESPOT can provide stabile and precise values. Magn Reson Med 73:161–169, 2015. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.25108

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 69

Metadata

Authors
Deoni, S. C. L., & Kolind, S. H.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2014-01-24
Volume
73
Issue
1
Pages
161-169
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1595872863
Cited by
69
References
4
FWCI
6.97
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigating the stability of mcDESPOT myelin water fraction values derived using a stochastic region contraction approach. https://app.cochat.ai/papers/10.1002/mrm.25108
The paper
Deoni, S. C. L., & Kolind, S. H. (2015). Investigating the stability of mcDESPOT myelin water fraction values derived using a stochastic region contraction approach. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.