CoChat

Comparison of myelin water fraction from multiecho T2 decay curve and steady‐state methods

Open access
Zhang, Jing, Kolind, Shannon H., Laule, Cornelia, MacKay, Alex L. · 2015 · Magnetic Resonance in Medicine
Cited by 90

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Purpose: Myelin water fraction is conventionally measured from the T 2 decay curve. Recently, a steady‐state approach entitled multicomponent‐driven equilibrium single pulse observation of T 1/T 2 (mcDESPOT) was employed for myelin water fraction mapping. However, no direct comparison between the established multiecho T 2 relaxation method and mcDESPOT has been performed. Methods: Gradient and spin echo (GRASE) acquired T 2 decay curve and mcDESPOT measurements were acquired from 10 healthy volunteers using a 3T MRI. We compared myelin water fraction, transmit radio frequency field (B 1), and T 2's of intra‐ and extracellular water obtained from both methods. Results: For all brain regions examined, myelin water fractions from mcDESPOT were significantly higher than those from multiecho GRASE. B 1 maps were qualitatively similar between GRASE and mcDESPOT, but multicomponent T 2 times were significantly different. To investigate the effect of exchange, mcDESPOT data were analyzed with and without exchange. When exchange was turned off, intra‐ and extracellular T 2 times from mcDESPOT were roughly consistent with GRASE results; however, myelin water fractions derived from mcDESPOT were still significantly higher than those derived from GRASE. Conclusion: Myelin water fraction values derived from mcDESPOT cannot be considered to be equivalent to those derived from T 2 decay curve approaches. Magn Reson Med 73:223–232, 2015. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.25125

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 90

Metadata

Authors
Zhang, J., Kolind, S. H., Laule, C., & MacKay, A. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2014-02-11
Volume
73
Issue
1
Pages
223-232
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1522438682
Cited by
90
References
5
FWCI
7.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of myelin water fraction from multiecho T2 decay curve and steady‐state methods. https://app.cochat.ai/papers/10.1002/mrm.25125
The paper
Zhang, J., Kolind, S. H., Laule, C., & MacKay, A. L. (2015). Comparison of myelin water fraction from multiecho T2 decay curve and steady‐state methods. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25125

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.