The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Low-rank plus sparse matrix decomposition for accelerated dynamic MRI with separation of background and dynamic components: L+S Reconstruction
Open accessAbstract
PURPOSE: To apply the low-rank plus sparse (L+S) matrix decomposition model to reconstruct undersampled dynamic MRI as a superposition of background and dynamic components in various problems of clinical interest. THEORY AND METHODS: The L+S model is natural to represent dynamic MRI data. Incoherence between k-t space (acquisition) and the singular vectors of L and the sparse domain of S is required to reconstruct undersampled data. Incoherence between L and S is required for robust separation of background and dynamic components. Multicoil L+S reconstruction is formulated using a convex optimization approach, where the nuclear norm is used to enforce low rank in L and the l1 norm is used to enforce sparsity in S. Feasibility of the L+S reconstruction was tested in several dynamic MRI experiments with true acceleration, including cardiac perfusion, cardiac cine, time-resolved angiography, and abdominal and breast perfusion using Cartesian and radial sampling. RESULTS: The L+S model increased compressibility of dynamic MRI data and thus enabled high-acceleration factors. The inherent background separation improved background suppression performance compared to conventional data subtraction, which is sensitive to motion. CONCLUSION: The high acceleration and background separation enabled by L+S promises to enhance spatial and temporal resolution and to enable background suppression without the need of subtraction or modeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
Beck, A., & Teboulle, M. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080716542 · Cited by 11,952
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 6,921
Self-citationA Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809
Self-citationGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
An iterative thresholding algorithm for linear inverse problems with a sparsity constraint.
Daubechies, I., Defrise, M., & De Mol, C. (2004) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20042 · Cited by 4,958
Exact Matrix Completion via Convex Optimization
Candès, E. J., & Recht, B. (2009) · Foundations of Computational Mathematics · doi:10.1007/s10208-009-9045-5 · Cited by 4,877
Self-citationSignal Recovery by Proximal Forward-Backward Splitting
Combettes, P. L., & Wajs, V. R. (2005) · Multiscale Modeling & Simulation · doi:10.1137/050626090 · Cited by 2,678
Nonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary Learning
Ravishankar, S., & Bresler, Y. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2090538 · Cited by 1,059
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
RASL: Robust Alignment by Sparse and Low-Rank Decomposition for Linearly Correlated Images
Peng, Y., Ganesh, A., Wright, J., Xu, W., & Ma, Y. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.282 · Cited by 817
Rank-Sparsity Incoherence for Matrix Decomposition
Chandrasekaran, V., Sanghavi, S., Parrilo, P. A., & Willsky, A. S. (2011) · SIAM Journal on Optimization · doi:10.1137/090761793 · Cited by 686
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 664
Otazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
Self-citationAccelerating SENSE using compressed sensing
Liang, D., Liu, B., Wang, J., & Ying, L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22161 · Cited by 474
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
Invited articles section foreword
Vianu, V. (2010) · Journal of the ACM · doi:10.1145/1870103.1870104 · Cited by 381
SPATIOTEMPORAL IMAGINGWITH PARTIALLY SEPARABLE FUNCTIONS
Liang, Z.-P. (2007) · 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2007.357020 · Cited by 369
Chandarana, H., Block, K. T., Rosenkrantz, A. B., Lim, R., Kim, D. C., Mossa, D. J., Babb, J. S., Kiefer, B., & Lee, V. S. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e31821eea45 · Cited by 299
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Chandarana, H., Feng, L., Block, T. K., Rosenkrantz, A. B., Lim, R. P., Babb, J. S., Sodickson, D. K., & Otazo, R. (2013) · Investigative Radiology · doi:10.1097/rli.0b013e318271869c · Cited by 248
Self-citationUnbiased Risk Estimates for Singular Value Thresholding and Spectral Estimators
Candes, E. J., Sing-Long, C. A., & Trzasko, J. D. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2270464 · Cited by 243
Robust principal component analysis-based four-dimensional computed tomography
Gao, H., Cai, J.-F., Shen, Z., & Zhao, H. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/11/002 · Cited by 181
Lim, R., Jacob, J. S., Hecht, E. M., Kim, D. C., Huffman, S. D., Kim, S., Babb, J. S., Laub, G. A., Adelman, M. A., & Lee, V. S. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22108 · Cited by 20
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
A deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
A Systematic Review of Compressive Sensing: Concepts, Implementations and Applications
Rani, M., Dhok, S. B., & Deshmukh, R. B. (2018) · IEEE Access · doi:10.1109/access.2018.2793851 · Cited by 530
Eo, T., Jun, Y., Kim, T., Jang, J., Lee, H., & Hwang, D. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27201 · Cited by 455
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & Webb, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 386
Metadata
- Authors
- Otazo, R., Candès, E., & Sodickson, D. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2014-04-23
- Volume
- 73
- Issue
- 3
- Pages
- 1125-1136
- ISSN
- 0740-3194 (ISSN-L)
- OpenAlex
- W2168903001
- Cited by
- 697
- References
- 32
- FWCI
- 35.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.