The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Robust principal component analysis-based four-dimensional computed tomography
Open accessAbstract
The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead of viewing the 4D object as a temporal collection of three-dimensional (3D) images and looking for local coherence in time or space independently, we perceive it as a mixture of low-rank matrix and sparse matrix to explore the maximum temporal coherence of the spatial structure among phases. Here the low-rank matrix corresponds to the 'background' or reference state, which is stationary over time or similar in structure; the sparse matrix stands for the 'motion' or time-varying component, e.g., heart motion in cardiac imaging, which is often either approximately sparse itself or can be sparsified in the proper basis. Besides 4D CT, this robust PCA-based 4D CT model should be applicable in other imaging problems for motion reduction or/and change detection with the least amount of data, such as multi-energy CT, cardiac MRI, and hyperspectral imaging. (2) A dynamic strategy for data acquisition, i.e. a temporally spiral scheme, is proposed that can potentially maintain similar reconstruction accuracy with far fewer projections of the data. The key point of this dynamic scheme is to reduce the total number of measurements, and hence the radiation dose, by acquiring complementary data in different phases while reducing redundant measurements of the common background structure. (3) An accurate, efficient, yet simple-to-implement algorithm based on the split Bregman method is developed for solving the model problem with sparse representation in tight frames.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM)
Gao, H., Yu, H., Osher, S., & Wang, G. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/11/115012 · Cited by 264
Self-citationDirect parametric reconstruction from undersampled (k,t)-space data in dynamic contrast enhanced MRI
Dikaios, N., Arridge, S., Hamy, V., Punwani, S., & Atkinson, D. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.05.001 · Cited by 40
Metadata
- Authors
- Gao, H., Cai, J.-F., Shen, Z., & Zhao, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-05-04
- Volume
- 56
- Issue
- 11
- Pages
- 3181-3198
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2111298039
- Cited by
- 181
- References
- 1
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust principal component analysis-based four-dimensional computed tomography. https://app.cochat.ai/papers/10.1088/0031-9155/56/11/002
- The paper
- Gao, H., Cai, J.-F., Shen, Z., & Zhao, H. (2011). Robust principal component analysis-based four-dimensional computed tomography. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/56/11/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.