How does magnetization transfer influence mc DESPOT results?
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose: A steady‐state approach that was termed multicomponent driven equilibrium single pulse observation of T 1 and T 2 (mcDESPOT) has recently been proposed for myelin water fraction (f M) mapping in brain development and demyelinating diseases. However, f M s estimated by mcDESPOT are significantly higher than myelin water fraction derived from multiecho spin echo T 2‐decay curve approaches. Magnetization transfer (MT), enhanced by the use of short, relatively high amplitude radiofrequency (RF) pulses in mcDESPOT, may artifactually influence f M maps. Our goal was to investigate the role of MT in mcDESPOT. Methods: mcDESPOT data was collected twice from three healthy volunteers using short RF pulses with higher MT effect and long RF pulses with lower MT effect. MR parameters from 11 white and gray regions were compared using a paired student t‐test. Whole slice difference images were also compared. Results: MT effects had a substantial influence on the signal generated by the balanced steady‐state free procession sequences used in mcDESPOT. However, these MT effects were not clearly evident in the f M values determined by the conventional two‐pool mcDESPOT analysis. Conclusion: The signal generated from mcDESPOT is sensitive to MT, but the extracted myelin water fractions are relatively insensitive to changes of MT. Magn Reson Med 74:1327–1335, 2015. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reaction Rates by Nuclear Magnetic Resonance
McConnell, H. M. (1958) · The Journal of Chemical Physics · doi:10.1063/1.1744152 · Cited by 1,624
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489 · cited 1×
“Equation [5] was also introduced to both short and long T2 pools to compensate for the MT effect during the finite RF pulse.”
BackgroundSelf-citationMagnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334
Self-citationOn the inherent precision of mcDESPOT
Lankford, C. L., & Does, M. D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24241 · Cited by 83
Cited by
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
Self-citationCortical maturation and myelination in healthy toddlers and young children
Deoni, S. C. L., Dean, D. C., Remer, J., Dirks, H., & O’Muircheartaigh, J. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.058 · Cited by 221
Hypomyelinating leukodystrophies — unravelling myelin biology
Wolf, N. I., ffrench-Constant, C., & van der Knaap, M. S. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00432-1 · Cited by 161
A multiparametric analysis of white matter maturation during late childhood and adolescence
Geeraert, B. L., Lebel, R. M., & Lebel, C. (2019) · Human Brain Mapping · doi:10.1002/hbm.24706 · Cited by 69
Lynn, J. D., Anand, C., Arshad, M., Homayouni, R., Rosenberg, D. R., Ofen, N., Raz, N., & Stanley, J. A. (2021) · Cerebral Cortex · doi:10.1093/cercor/bhaa272 · Cited by 33
“The inconsistency may stem from the use of the mcDESPOT, an approach that has been criticized for confounding magnetization transfer effects (Zhang et al. 2015) and the”
Method
Metadata
- Authors
- Zhang, J., Kolind, S. H., Laule, C., & MacKay, A. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2014-11-14
- Volume
- 74
- Issue
- 5
- Pages
- 1327-1335
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2111947559
- Cited by
- 45
- References
- 4
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How does magnetization transfer influence mc DESPOT results? https://app.cochat.ai/papers/10.1002/mrm.25520
- The paper
- Zhang, J., Kolind, S. H., Laule, C., & MacKay, A. L. (2015). How does magnetization transfer influence mc DESPOT results? Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25520
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.