CoChat

How does magnetization transfer influence mc DESPOT results?

Open access
Zhang, Jing, Kolind, Shannon H., Laule, Cornelia, MacKay, Alex L. · 2015 · Magnetic Resonance in Medicine
Cited by 45

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Purpose: A steady‐state approach that was termed multicomponent driven equilibrium single pulse observation of T 1 and T 2 (mcDESPOT) has recently been proposed for myelin water fraction (f M) mapping in brain development and demyelinating diseases. However, f M s estimated by mcDESPOT are significantly higher than myelin water fraction derived from multiecho spin echo T 2‐decay curve approaches. Magnetization transfer (MT), enhanced by the use of short, relatively high amplitude radiofrequency (RF) pulses in mcDESPOT, may artifactually influence f M maps. Our goal was to investigate the role of MT in mcDESPOT. Methods: mcDESPOT data was collected twice from three healthy volunteers using short RF pulses with higher MT effect and long RF pulses with lower MT effect. MR parameters from 11 white and gray regions were compared using a paired student t‐test. Whole slice difference images were also compared. Results: MT effects had a substantial influence on the signal generated by the balanced steady‐state free procession sequences used in mcDESPOT. However, these MT effects were not clearly evident in the f M values determined by the conventional two‐pool mcDESPOT analysis. Conclusion: The signal generated from mcDESPOT is sensitive to MT, but the extracted myelin water fractions are relatively insensitive to changes of MT. Magn Reson Med 74:1327–1335, 2015. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.25520

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 45

Metadata

Authors
Zhang, J., Kolind, S. H., Laule, C., & MacKay, A. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2014-11-14
Volume
74
Issue
5
Pages
1327-1335
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2111947559
Cited by
45
References
4
FWCI
3.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: How does magnetization transfer influence mc DESPOT results? https://app.cochat.ai/papers/10.1002/mrm.25520
The paper
Zhang, J., Kolind, S. H., Laule, C., & MacKay, A. L. (2015). How does magnetization transfer influence mc DESPOT results? Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25520

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.