PGSE,OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Purpose: To identify optimal pulsed gradient spin‐echo (PGSE) and oscillating gradient spin‐echo (OGSE) sequence settings for maximizing sensitivity to axon diameter in idealized and practical conditions. Methods: Simulations on a simple two‐compartment white matter model (with nonpermeable cylinders) are used to investigate a wide space of clinically plausible PGSE and OGSE sequence parameters with trapezoidal diffusion gradient waveforms. Signal sensitivity is measured as a derivative of the signal with respect to axon diameter. Models of parallel and dispersed fibers are investigated separately to represent idealized and practical conditions. Results: Simulations show that, for the simple case of gradients perfectly perpendicular to straight parallel fibers, PGSE always gives maximum sensitivity. However, in real‐world scenarios where fibers have unknown and dispersed orientation, low‐frequency OGSE provides higher sensitivity. Maximum sensitivity results show that on current clinical scanners (Gmax = 60 mT/m, signal to noise ratio (SNR) = 20) axon diameters below 6 µm are indistinguishable from zero. Scanners with stronger gradient systems such as the Massachusetts General Hospital (MGH) Connectom scanner (Gmax = 300 mT/m) can extend this sensitivity limit down to 2–3 µm, probing a much greater proportion of the underlying axon diameter distribution. Conclusion: Low‐frequency OGSE provides additional sensitivity to PGSE in practical situations. OGSE is particularly advantageous for systems with high performance gradients. Magn Reson Med 75:688–700, 2016. © 2015 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 3×
“Maximum intensity points are marked with a black star: ðG; d;NÞ 1⁄4 (300,36,1); (300,29,1); (300,17,1); (300,11,1) for a 1⁄4 2; 4; 6; 8 mm, respectively.”
MethodNODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Self-citationRice, D., & Barone, S. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108s3511 · Cited by 2,944 · cited 2×
“Maximum intensity points are marked with a black star: ðG; d;NÞ 1⁄4 [(300,29,4) (300,20,2) (300,18,2)]; [(300,26,4) (300,27,4) (300,17,2)] for ðk; aÞ 1⁄4[(16, 2) (16,4) (16, 6)]; [(8, 2) (8, 4) (8, 6)], respectively.”
BackgroundComposite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856 · cited 1×
“The first one is a simplified version of the CHARMED model (31,32) described in (33).”
MethodAxcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 1×
“A number of techniques to measure axon diameter statistics using diffusion MRI have been proposed in the literature such as AxCaliber (9,10), ActiveAx (11–13), double pulsed field gradient (14–16), and Q-space imaging (17).”
MethodOrientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Self-citationAssaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
Autism: The first firm finding = underconnectivity?
Hughes, J. R. (2007) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2007.03.010 · Cited by 156
Probing mouse brain microstructure using oscillating gradient diffusion MRI
Aggarwal, M., Jones, M. V., Calabresi, P. A., Mori, S., & Zhang, J. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22981 · Cited by 117 · cited 1×
“We constrain N to be an integer number as is most typically used for OGSE methods (39,40).”
Method
Cited by
Investigating white matter fibre density and morphology using fixel-based analysis.
Raffelt, D. A., Tournier, J.-D., Smith, R. E., Vaughan, D. N., Jackson, G., Ridgway, G. R., & Connelly, A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.029 · Cited by 620
“However, most white matter voxels are known to contain crossing fibres (Jeurissen et al., 2012), and voxel-averaged measures such as FA are not fibre-specific (or even erroneous) in such regions, which confounds interpretation of apparent differences (Douaud et al., 2011; Pierpaoli et al., 2001;…”
BackgroundQuantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Self-citationMulti-compartment microscopic diffusion imaging
Kaden, E., Kelm, N. D., Carson, R. P., Does, M. D., & Alexander, D. C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.002 · Cited by 345
“Hereafter we shall ignore biophysical models (see Panagiotaki et al. (2012) for a review) that aim to recover structural parameters like the axon diameter because current clinical scanners (with |G|≤100 mT/m) lack sensitivity to such features (Drobnjak et al., 2016).”
BackgroundMethodSelf-citationStudying neuroanatomy using MRI
Lerch, J. P., van der Kouwe, A. J. W., Raznahan, A., Paus, T., Johansen-Berg, H., Miller, K. L., Smith, S. M., Fischl, B., & Sotiropoulos, S. N. (2017) · Nature Neuroscience · doi:10.1038/nn.4501 · Cited by 310
Metadata
- Authors
- Drobnjak, I., Zhang, H., Ianuş, A., Kaden, E., & Alexander, D. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2015-03-25
- Volume
- 75
- Issue
- 2
- Pages
- 688-700
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2149778524
- Cited by
- 128
- References
- 9
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PGSE,OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study. https://app.cochat.ai/papers/10.1002/mrm.25631
- The paper
- Drobnjak, I., Zhang, H., Ianuş, A., Kaden, E., & Alexander, D. C. (2016). PGSE,OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25631
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.