The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Diffusion MRI noise mapping using random matrix theory
Open accessAbstract
Purpose: To estimate the spatially varying noise map using a redundant series of magnitude MR images. Methods: We exploit redundancy in non‐Gaussian distributed multidirectional diffusion MRI data by identifying its noise‐only principal components, based on the theory of noisy covariance matrices. The bulk of principal component analysis eigenvalues, arising due to noise, is described by the universal Marchenko–Pastur distribution, parameterized by the noise level. This allows us to estimate noise level in a local neighborhood based on the singular value decomposition of a matrix combining neighborhood voxels and diffusion directions. Results: We present a model‐independent local noise mapping method capable of estimating the noise level down to about 1% error. In contrast to current state‐of‐the‐art techniques, the resultant noise maps do not show artifactual anatomical features that often reflect physiological noise, the presence of sharp edges, or a lack of adequate a priori knowledge of the expected form of MR signal. Conclusions: Simulations and experiments show that typical diffusion MRI data exhibit sufficient redundancy that enables accurate, precise, and robust estimation of the local noise level by interpreting the principal component analysis eigenspectrum in terms of the Marchenko–Pastur distribution. Magn Reson Med 76:1582–1593, 2016. © 2015 International Society for Magnetic Resonance in Medicine
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIII. On lines and planes of closest fit to systems of points in space
Pearson, K. (1901) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440109462720 · Cited by 11,934
Analysis of a complex of statistical variables into principal components.
Hotelling, H. (1933) · Journal of Educational Psychology · doi:10.1037/h0071325 · Cited by 9,633
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Statistical Theory of the Energy Levels of Complex Systems. I
Dyson, F. J. (1962) · Journal of Mathematical Physics · doi:10.1063/1.1703773 · Cited by 2,266
Lower Limit for the Energy Derivative of the Scattering Phase Shift
Wigner, E. P. (1955) · Physical Review · doi:10.1103/physrev.98.145 · Cited by 2,010
DISTRIBUTION OF EIGENVALUES FOR SOME SETS OF RANDOM MATRICES
Marčenko, V. A., & Pastur, L. A. (1967) · Mathematics of the USSR-Sbornik · doi:10.1070/sm1967v001n04abeh001994 · Cited by 1,713
Methods for Solving Incorrectly Posed Problems
Morozov, V. A. (1984) · Springer eBooks · doi:10.1007/978-1-4612-5280-1 · Cited by 1,357
Noise Dressing of Financial Correlation Matrices
Laloux, L., Cizeau, P., Bouchaud, J.-P., & Potters, M. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.1467 · Cited by 1,241
Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
The sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
Second order total generalized variation (TGV) for MRI
Knoll, F., Bredies, K., Pock, T., & Stollberger, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22595 · Cited by 634
RESTORE: Robust estimation of tensors by outlier rejection
Chang, L., Jones, D. K., & Pierpaoli, C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20426 · Cited by 606
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Veraart, J., Sijbers, J., Sunaert, S., Leemans, A., & Jeurissen, B. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.028 · Cited by 504
Self-citationA Method for Selecting the Bin Size of a Time Histogram
Shimazaki, H., & Shinomoto, S. (2007) · Neural Computation · doi:10.1162/neco.2007.19.6.1503 · Cited by 454
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 438
Diffusion Weighted Image Denoising Using Overcomplete Local PCA
Manjón, J. V., Coupé, P., Concha, L., Buades, A., Collins, D. L., & Robles, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073021 · Cited by 417
Maximum-likelihood estimation of Rician distribution parameters
Sijbers, J., den Dekker, A. J., Scheunders, P., & Van Dyck, D. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712125 · Cited by 393
Distributions of singular values for some random matrices
Sengupta, A. M., & Mitra, P. P. (1999) · Physical Review E · doi:10.1103/physreve.60.3389 · Cited by 358
Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
Koay, C. G., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.01.016 · Cited by 312
Robust Rician noise estimation for MR images
Coupé, P., Manjón, J. V., Gedamu, E., Arnold, D., Robles, M., & Collins, D. L. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.03.001 · Cited by 239
Imagerie de diffusion in-vivo par résonance magnétique nucléaire
Bihan, D. L., & Breton, E. (1985) · HAL · Cited by 238
Sotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J. L., Auerbach, E. J., Yacoub, E., Feinberg, D., Setsompop, K., Wald, L. L., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24623 · Cited by 186
Formal characterization and extension of the linearized diffusion tensor model
Salvador, R., Peña, A., Menon, D. K., Carpenter, T. A., Pickard, J. D., & Bullmore, E. T. (2005) · Human Brain Mapping · doi:10.1002/hbm.20076 · Cited by 171
Gibbs ringing in diffusion MRI
Veraart, J., Fieremans, E., Jelescu, I., Knöll, F., & Novikov, D. S. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25866 · Cited by 152
Self-citationSuppression of MRI Truncation Artifacts Using Total Variation Constrained Data Extrapolation
Block, K. T., Uecker, M., & Frahm, J. (2008) · International Journal of Biomedical Imaging · doi:10.1155/2008/184123 · Cited by 122
The effect of Gibbs ringing artifacts on measures derived from diffusion MRI
Perrone, D., Aelterman, J., Pižurica, A., Jeurissen, B., Philips, W. R., & Leemans, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.068 · Cited by 120
Comprehensive framework for accurate diffusion MRI parameter estimation
Veraart, J., Rajan, J., Peeters, R., Leemans, A., Sunaert, S., & Sijbers, J. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24529 · Cited by 102
Self-citationVeraart, J., Hecke, W. V., & Sijbers, J. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22835 · Cited by 100
Self-citationStatistical noise analysis in GRAPPA using a parametrized noncentral Chi approximation model
Aja‐Fernández, S., Tristán‐Vega, A., & Hoge, W. S. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22701 · Cited by 93
Spatially variant noise estimation in MRI: A homomorphic approach
Aja‐Fernández, S., Pieciak, T., & Vegas‐Sánchez‐Ferrero, G. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.11.005 · Cited by 77
(2012) · Oxford University Press eBooks · doi:10.1093/med/9780195369779.001.0001 · Cited by 75
Collier, Q., Veraart, J., Jeurissen, B., den Dekker, A. J., & Sijbers, J. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25351 · Cited by 65
Self-citationSpatially variable Rician noise in magnetic resonance imaging
Maximov, I. I., Farrher, E., Grinberg, F., & Shah, N. J. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.12.002 · Cited by 49
A simple noise correction scheme for diffusional kurtosis imaging
Glenn, G. R., Tabesh, A., & Jensen, J. H. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.08.028 · Cited by 46
Estimation and application of spatially variable noise fields in diffusion tensor imaging
Landman, B. A., Bazin, P., & Prince, J. L. (2009) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2009.01.001 · Cited by 37
A method to assess spatially variant noise in dynamic MR image series
Ding, Y., Chung, Y., & Simonetti, O. P. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22258 · Cited by 32
Local estimation of the noise level in MRI using structural adaptation
Tabelow, K., Voss, H. U., & Polzehl, J. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.10.008 · Cited by 23
Feasibility and Advantages of Diffusion Weighted Imaging Atlas Construction in Q-Space
Dhollander, T., Veraart, J., Hecke, W. V., Maes, F., Sunaert, S. G., Sijbers, J., & Suetens, P. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23629-7_21 · Cited by 13
Self-citationNoise Variance Estimation for Spectrum Sensing in Cognitive Radio Networks
Ahmed, A., Hu, Y. F., & Noras, J. M. (2014) · AASRI Procedia · doi:10.1016/j.aasri.2014.09.008 · Cited by 13
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Self-citationQuantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Self-citationDegeneracy in model parameter estimation for multi‐compartmental diffusion in neuronal tissue
Jelescu, I. O., Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3450 · Cited by 316
Self-citationFibre-specific white matter reductions in Alzheimer’s disease and mild cognitive impairment
Mito, R., Raffelt, D., Dhollander, T., Vaughan, D. N., Tournier, J.-D., Salvado, O., Brodtmann, A., Rowe, C. C., Villemagne, V. L., & Connelly, A. (2018) · Brain · doi:10.1093/brain/awx355 · Cited by 309
TE dependent Diffusion Imaging (TEdDI) distinguishes between compartmental T2 relaxation times
Veraart, J., Novikov, D. S., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.030 · Cited by 212
Self-citation
Metadata
- Authors
- Veraart, J., Fieremans, E., & Novikov, D. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2015-11-24
- Volume
- 76
- Issue
- 5
- Pages
- 1582-1593
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2177917702
- Cited by
- 773
- References
- 43
- FWCI
- 16.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.