The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
MR fingerprinting for rapid quantification of myocardial T1, T2, and proton spin density: Cardiac MR Fingerprinting for T1, T2, and M0Mapping
Open accessAbstract
Purpose To introduce a two-dimensional MR fingerprinting (MRF) technique for quantification of T1, T2, and M0 in myocardium. Methods An electrocardiograph-triggered MRF method is introduced for mapping myocardial T1, T2, and M0 during a single breath-hold in as short as four heartbeats. The pulse sequence uses variable flip angles, repetition times, inversion recovery times, and T2 preparation dephasing times. A dictionary of possible signal evolutions is simulated for each scan that incorporates the subject's unique variations in heart rate. Aspects of the sequence design were explored in simulations, and the accuracy and precision of cardiac MRF were assessed in a phantom study. In vivo imaging was performed at 3 Tesla in 11 volunteers to generate native parametric maps. Results T1 and T2 measurements from the proposed cardiac MRF sequence correlated well with standard spin echo measurements in the phantom study (R2 > 0.99). A Bland-Altman analysis revealed good agreement for myocardial T1 measurements between MRF and MOLLI (bias 1 ms, 95% limits of agreement −72 to 72 ms) and T2 measurements between MRF and T2-prepared balanced steady-state free precession (bias, −2.6 ms; 95% limits of agreement, −8.5 to 3.3 ms). Conclusion MRF can provide quantitative single slice T1, T2, and M0 maps in the heart within a single breath-hold. Magn Reson Med 77:1446–1458, 2017. © 2016 International Society for Magnetic Resonance in Medicine
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 2×
“As described in Ma et al (28), a k-space trajectory is chosen that produces spatially and temporally incoherent artifacts when undersampled, which aids in the pattern matching step.”
BackgroundT1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Cited by
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Cardiac MRI Endpoints in Myocardial Infarction Experimental and Clinical Trials
Ibanez, B., Aletras, A. H., Arai, A. E., Arheden, H., Bax, J., Berry, C., Bucciarelli-Ducci, C., Croisille, P., Dall'Armellina, E., Dharmakumar, R., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.05.024 · Cited by 369
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
Self-citation
Metadata
- Authors
- Hamilton, J. I., Jiang, Y., Chen, Y., Ma, D., Lo, W.-C., Griswold, M., & Seiberlich, N.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2016-04-01
- Volume
- 77
- Issue
- 4
- Pages
- 1446-1458
- ISSN
- 0740-3194 (ISSN-L)
- OpenAlex
- W2330484003
- Cited by
- 246
- References
- 3
- FWCI
- 18.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.