Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling

Open access
Zhao, Bo, Setsompop, Kawin, Adalsteinsson, Elfar, Gagoski, Borjan, Ye, Huihui, Ma, Dan, Jiang, Yun, Ellen Grant, P., Griswold, Mark A., Wald, Lawrence L. · 2018 · Magnetic Resonance in Medicine

Abstract

Purpose: This article introduces a constrained imaging method based on low‐rank and subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). Theory and Methods: A new model‐based imaging method is developed for MRF to reconstruct high‐quality time‐series images and accurate tissue parameter maps (e.g., T1, T2, and spin density maps). Specifically, the proposed method exploits low‐rank approximations of MRF time‐series images, and further enforces temporal subspace constraints to capture magnetization dynamics. This allows the time‐series image reconstruction problem to be formulated as a simple linear least‐squares problem, which enables efficient computation. After image reconstruction, tissue parameter maps are estimated via dictionary‐based pattern matching, as in the conventional approach. Results: The effectiveness of the proposed method was evaluated with in vivo experiments. Compared with the conventional MRF reconstruction, the proposed method reconstructs time‐series images with significantly reduced aliasing artifacts and noise contamination. Although the conventional approach exhibits some robustness to these corruptions, the improved time‐series image reconstruction in turn provides more accurate tissue parameter maps. The improvement is pronounced especially when the acquisition time becomes short. Conclusions: The proposed method significantly improves the accuracy of MRF, and also reduces data acquisition time. Magn Reson Med 79:933–942, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.26701

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Magnetic resonance fingerprinting

    Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 1×

    “In MRF, the contrast-weighted image I m ð x Þ can be expressed as (2,3): (2,3,5,6) form the following data model: ; [3] by combining Equation [1] with [2].”
    Method

Cited by

See all 179

Metadata

Authors
Zhao, B., Setsompop, K., Adalsteinsson, E., Gagoski, B., Ye, H., Ma, D., Jiang, Y., Ellen Grant, P., Griswold, M. A., & Wald, L. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2017-04-15
Volume
79
Issue
2
Pages
933-942
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2606182999
Cited by
179
References
1
FWCI
11.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.