Scanner invariant representations for diffusion MRI harmonization
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Purpose: In the present work, we describe the correction of diffusion‐weighted MRI for site and scanner biases using a novel method based on invariant representation. Theory and Methods: Pooled imaging data from multiple sources are subject to variation between the sources. Correcting for these biases has become very important as imaging studies increase in size and multi‐site cases become more common. We propose learning an intermediate representation invariant to site/protocol variables, a technique adapted from information theory‐based algorithmic fairness; by leveraging the data processing inequality, such a representation can then be used to create an image reconstruction that is uninformative of its original source, yet still faithful to underlying structures. To implement this, we use a deep learning method based on variational auto‐encoders (VAE) to construct scanner invariant encodings of the imaging data. Results: To evaluate our method, we use training data from the 2018 MICCAI Computational Diffusion MRI (CDMRI) Challenge Harmonization dataset. Our proposed method shows improvements on independent test data relative to a recently published baseline method on each subtask, mapping data from three different scanning contexts to and from one separate target scanning context. Conclusions: As imaging studies continue to grow, the use of pooled multi‐site imaging will similarly increase. Invariant representation presents a strong candidate for the harmonization of these data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Adjusting batch effects in microarray expression data using empirical Bayes methods
Johnson, W. E., Li, C., & Rabinovic, A. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj037 · Cited by 8,658 · cited 4×
“This latter method was adapted from genomics literature [14], and employs a variational Bayes scheme to learn model coefficients.”
BackgroundMethodInfluentialThe minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
MRtrix3: A fast, flexible and open software framework for medical image processing and visualisation
Tournier, J.-D., Smith, R., Raffelt, D., Tabbara, R., Dhollander, T., Pietsch, M., Christiaens, D., Jeurissen, B., Yeh, C.-H., & Connelly, A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116137 · Cited by 3,687
Andersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
Diffusion tensor imaging (DTI)-based white matter mapping in brain research: a review
Assaf, Y., & Pasternak, O. (2008) · Journal of Molecular Neuroscience · doi:10.1007/s12031-007-0029-0 · Cited by 1,537 · cited 1×
“for a review [6]).”
Harmonization of multi-site diffusion tensor imaging data
Fortin, J.-P., Parker, D., Tunç, B., Watanabe, T., Elliott, M. A., Ruparel, K., Roalf, D. R., Satterthwaite, T. D., Gur, R. C., Gur, R. E., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.047 · Cited by 1,261 · cited 2×
“Harmonization of summary statistics (voxel-wise or region-wise) include random/ mixed-effect models(7) as well as the scale-and-shift random effects regression of ComBat.(2,7) This latter method was adapted from the genomics literature,(23) and employs a variational Bayes scheme to learn model coefficients.”
MethodKelly, S., Jahanshad, N., Zalesky, A., Kochunov, P., Agartz, I., Alloza, C., Andreassen, O. A., Arango, C., Banaj, N., Bouix, S., et al. (2018) · Molecular Psychiatry · doi:10.1038/mp.2017.170 · Cited by 701 · cited 1×
“In magnetic resonance imaging (MRI), variations in scanner characteristics such as its magnetic field strength, scanner vendor, receiver coil hardware, applied gradient fields, or primary image reconstruction methods have strong effects on collected data [7,9,15]; multi-site studies in particular are subject to these…”
BackgroundSelf-citationBrown, C. E. (1998) · Applied Multivariate Statistics in Geohydrology and Related Sciences · doi:10.1007/978-3-642-80328-4_13 · Cited by 528
Cited by
Chen, Z., Pawar, K., Ekanayake, M., Pain, C., Zhong, S., & Egan, G. F. (2022) · Journal of Digital Imaging · doi:10.1007/s10278-022-00721-9 · Cited by 224
“Variational autoencoder (VAE) was applied for applications including correcting motion artefacts [17] and normalizing multi-site image data [18].”
BackgroundMethodMali, S. A., Ibrahim, A., Woodruff, H. C., Andrearczyk, V., Müller, H., Primakov, S., Salahuddin, Z., Chatterjee, A., & Lambin, P. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11090842 · Cited by 207
“Methods using coefficients of spherical harmonics to harmonize diffusion MRI have been explored [61,71–73].”
MethodDeep learning for small and big data in psychiatry
Koppe, G., Meyer-Lindenberg, A., & Durstewitz, D. (2021) · Neuropsychopharmacology · doi:10.1038/s41386-020-0767-z · Cited by 189
Deep learning-based unlearning of dataset bias for mri harmonisation and confound removal
Dinsdale, N. K., Jenkinson, M., & Namburete, A. I. L. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117689 · Cited by 178
Jack, C. R., Arani, A., Borowski, B. J., Cash, D. M., Crawford, K., Das, S. R., DeCarli, C., Fletcher, E., Fox, N. C., Gunter, J. L., et al. (2024) · Alzheimer's & Dementia · doi:10.1002/alz.14166 · Cited by 82
Self-citation
Metadata
- Authors
- Moyer, D., Ver Steeg, G., Tax, C. M. W., & Thompson, P. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2020-04-06
- Volume
- 84
- Issue
- 4
- Pages
- 2174-2189
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2936596052
- Cited by
- 123
- References
- 12
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scanner invariant representations for diffusion MRI harmonization. https://app.cochat.ai/papers/10.1002/mrm.28243
- The paper
- Moyer, D., Ver Steeg, G., Tax, C. M. W., & Thompson, P. M. (2020). Scanner invariant representations for diffusion MRI harmonization. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.28243
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.