CoChat

Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T

Neggers, Sebastiaan F. W., Hermans, Erno J., Ramsey, Nick F. · 2008 · NMR in Biomedicine
Cited by 118

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A major impetus in functional MRI development is to enhance sensitivity to changes in neural activity. One way to improve sensitivity is to enhance contrast to noise ratio, for instance by increasing field strength or the number of receiving coils. If these parameters are fixed, there is still the possibility to optimize scans by altering speed or signal strength [signal‐to‐noise ratio (SNR)]. We here demonstrate a very fast whole‐brain scan, by combining a three‐dimensional (3D)‐PRESTO (principle of echo shifting with a train of observations) pulse sequence with a commercial eight‐channel head coil and sensitivity encoding (SENSE). 3D‐PRESTO uses time optimally by means of echo shifting. Moreover, 3D scans can accommodate SENSE in two directions, reducing scan time proportionally. The present PRESTO–SENSE sequence achieves full brain coverage within 500 ms. We compared this with a two‐dimensional (2D) echo planar imaging (EPI) scan with identical brain coverage on 10 volunteers. Resting‐state temporal SNR in the blood‐oxygen‐level‐dependent (BOLD) frequency range and T‐statistics for thumb movement and visual checkerboard activations were compared. Results show improved temporal SNR across the brain for PRESTO–SENSE compared with EPI. The percentage signal change and relative standard deviation of the noise were smaller for PRESTO–SENSE. Sensitivity for brain activation, as reflected by T‐values, was consistently higher for PRESTO, and this seemed to be mainly due to the increased number of observations within a fixed time period. We conclude that PRESTO accelerated with SENSE in two directions can be more sensitive to BOLD signal changes than the widely used 2D‐EPI, when a fixed amount of time is available for functional MRI scanning. Copyright © 2008 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.1235

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 118

Metadata

Authors
Neggers, S. F. W., Hermans, E. J., & Ramsey, N. F.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2008-01-14
Volume
21
Issue
7
Pages
663-676
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W1977713172
Cited by
118
References
3
FWCI
10.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T. https://app.cochat.ai/papers/10.1002/nbm.1235
The paper
Neggers, S. F. W., Hermans, E. J., & Ramsey, N. F. (2008). Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T. NMR in Biomedicine. https://doi.org/10.1002/nbm.1235

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.