Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A major impetus in functional MRI development is to enhance sensitivity to changes in neural activity. One way to improve sensitivity is to enhance contrast to noise ratio, for instance by increasing field strength or the number of receiving coils. If these parameters are fixed, there is still the possibility to optimize scans by altering speed or signal strength [signal‐to‐noise ratio (SNR)]. We here demonstrate a very fast whole‐brain scan, by combining a three‐dimensional (3D)‐PRESTO (principle of echo shifting with a train of observations) pulse sequence with a commercial eight‐channel head coil and sensitivity encoding (SENSE). 3D‐PRESTO uses time optimally by means of echo shifting. Moreover, 3D scans can accommodate SENSE in two directions, reducing scan time proportionally. The present PRESTO–SENSE sequence achieves full brain coverage within 500 ms. We compared this with a two‐dimensional (2D) echo planar imaging (EPI) scan with identical brain coverage on 10 volunteers. Resting‐state temporal SNR in the blood‐oxygen‐level‐dependent (BOLD) frequency range and T‐statistics for thumb movement and visual checkerboard activations were compared. Results show improved temporal SNR across the brain for PRESTO–SENSE compared with EPI. The percentage signal change and relative standard deviation of the noise were smaller for PRESTO–SENSE. Sensitivity for brain activation, as reflected by T‐values, was consistently higher for PRESTO, and this seemed to be mainly due to the increased number of observations within a fixed time period. We conclude that PRESTO accelerated with SENSE in two directions can be more sensitive to BOLD signal changes than the widely used 2D‐EPI, when a fixed amount of time is available for functional MRI scanning. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Cited by
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
van den Heuvel, M. P., Stam, C. J., Boersma, M., & Hulshoff Pol, H. E. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.010 · Cited by 724
van den Heuvel, M., Mandl, R., Luigjes, J., & Hulshoff Pol, H. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2964-08.2008 · Cited by 349
“During the rest experiment, resting-state blood oxygenation level-dependent (BOLD) signals were recorded during a period of 8 min using a fast fMRI sequence [three-dimensional (3D) PRESTOSENSE p/s-reduction 2/2 (Golay et al., 2000; Neggers et al., 2008); repetition time (TR)/echo time (TE), 22 ms/32 ms using shifted e…”
MethodInfluentialAuditory verbal hallucinations predominantly activate the right inferior frontal area
Sommer, I. E. C., Diederen, K. M. J., Blom, J.-D., Willems, A., Kushan, L., Slotema, K., Boks, M. P. M., Daalman, K., Hoek, H. W., Neggers, S. F. W., et al. (2008) · Brain · doi:10.1093/brain/awn251 · Cited by 297
Self-citationThree dimensional echo-planar imaging at 7 Tesla
Poser, B. A., Koopmans, P. J., Witzel, T., Wald, L. L., & Barth, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.108 · Cited by 284
Metadata
- Authors
- Neggers, S. F. W., Hermans, E. J., & Ramsey, N. F.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2008-01-14
- Volume
- 21
- Issue
- 7
- Pages
- 663-676
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1977713172
- Cited by
- 118
- References
- 3
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T. https://app.cochat.ai/papers/10.1002/nbm.1235
- The paper
- Neggers, S. F. W., Hermans, E. J., & Ramsey, N. F. (2008). Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T. NMR in Biomedicine. https://doi.org/10.1002/nbm.1235
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.