Comparison of diffusion‐weighted MRI with changes in cell volume in a rat model of brain injury
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The precise mechanisms that underlie acute changes in tissue water diffusion following cerebral ischemia or related insults such as glutamate exposure remain unexplained, but it has been suggested that these may be caused by cell swelling due to water uptake. This study was undertaken to compare the changes observed in diffusion‐weighted MR images with changes in the cellular volume measured by electrical impedance in a model of N‐methyl‐D‐aspartate‐induced brain injury in perinatal rats. The results show that the temporal course of the intensity changes in the diffusion‐weighted images parallelled the progressive shrinkage of the extracellular space measured from the electrical impedance. After administration of the N‐methyl‐D‐aspartate antagonist MK‐801 the signal enhancement in the images was reversed, which paralleled the normalization of the extracellular space observed by the impedance measurements. It was estimated that the extracellular space decreased from 24 to 12% while the apparent diffusion coefficient of water decreased from 0.89×10−9 in normal tissue to 0.42×10−9 m 2/s in tissue exposed to N‐methyl‐D‐aspartate. These data indicate that changes in tissue water diffusion are related to changes in cell volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Cited by
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Self-citationMagnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Dijkhuizen, R. M., Singhal, A. B., Mandeville, J. B., Wu, O., Halpern, E. F., Finklestein, S. P., Rosen, B. R., & Lo, E. H. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-02-00510.2003 · Cited by 280
van der Toorn, A., Syková, E., Dijkhuizen, R. M., Vořišek, I., Vargová, L., Škobisová, E., van Lookeren Campagne, M., Reese, T., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360110 · Cited by 270
Self-citationAlbers, G. W. (1999) · Stroke · doi:10.1161/01.str.30.10.2230 · Cited by 253
Metadata
- Authors
- Verheul, H. B., Balazs, R., Berkelbach van der Sprenkel, J. W., Tulleken, C. A. F., Nicolay, K., Tamminga, K. S., & van Lookeren Campagne, M.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 1994-03
- Volume
- 7
- Issue
- 1-2
- Pages
- 96-100
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2059550812
- Cited by
- 135
- References
- 3
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of diffusion‐weighted MRI with changes in cell volume in a rat model of brain injury. https://app.cochat.ai/papers/10.1002/nbm.1940070115
- The paper
- Verheul, H. B., Balazs, R., Berkelbach van der Sprenkel, J. W., Tulleken, C. A. F., Nicolay, K., Tamminga, K. S., & van Lookeren Campagne, M. (1994). Comparison of diffusion‐weighted MRI with changes in cell volume in a rat model of brain injury. NMR in Biomedicine. https://doi.org/10.1002/nbm.1940070115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.