Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Diffusion MRI: Precision, accuracy and flow effects

Conturo, Thomas E., McKinstry, Robert C., Aronovitz, Joseph A., Neil, Jeffrey J.·1995·NMR in Biomedicine

Abstract

After a decade of evolution and application of diffusion imaging, a large body of literature has been accumulated. It is in this context that the accuracy and precision of diffusion‐weighted and quantitative diffusion MRI are reviewed. The emphasis of the review is on practical methods for clinical human imaging, particularly in the brain. The requirements for accuracy and precision are reviewed for various clinical and basic science applications. The methods of measuring and calculating diffusion effects with MRI are reviewed. The pulse gradient spin echo (PGSE) methods are emphasized as these methods are used most commonly in the clinical setting. Processing of PGSE data is reviewed. Various PGSE encoding schemes are also reviewed in terms of the accuracy and precision of isotropic and anisotropic diffusion measurements. The broad range of factors impacting the accuracy of the PGSE methods and other encoding schemes is then considered. Firstly, system inaccuracies such as background imaging gradients, gradient linearity, refocusing RF pulses, eddy currents, image misregistration, noise and dynamic range are considered. A second class of inaccuracies is contributed by the bulk effects of the imaged object, and include sample background gradients, subject motion of cerebrospinal fluid and organs, and aperiodic organ motion. A final category of potential inaccuracies is classified as being contributed by microscopic, biophysical tissue properties and include partial volume effects, anisotropy, restriction, diffusion distance, compartmentation, exchange, multiexponential diffusion decay, T2 weighting and microvascular perfusion. Finally, the application of diffusion methods to studies of blood flow in the microvasculature (i.e. the arterioles, capillaries and venules) are reviewed in detail, particularly in terms of feasibility and the stringent accuracy and precision requirements. Recent provocative studies examining the use of PGSE approaches to suppress microvascular signals in brain functional MRI (fMRI) are also reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.1940080706

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 211

Metadata

Authors
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
1995-11
Volume
8
Issue
7
Pages
307-332
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2043858070
Cited by
211
References
7
FWCI
3.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diffusion MRI: Precision, accuracy and flow effects. https://app.cochat.ai/papers/10.1002/nbm.1940080706
The paper
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995). Diffusion MRI: Precision, accuracy and flow effects. NMR in Biomedicine. https://doi.org/10.1002/nbm.1940080706

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.